Optimization of Ankle-Foot Prosthesis with Active Alignment by Passive Elements

نویسندگان

  • Farahnaz Rahmani Department of Mechatronic Engineering, South Tehran Branch, Islamic Azad University, Tehran, Iran
  • Hassan Zohoor Center of Excellence in Design, Robotics and Automation, Sharif University of Technology; Academician, Academy of Sciences of IR Iran
چکیده مقاله:

Today, often ankle’s active prosthesis is used for transtibial amputated people’s walking, because these prostheses have some advantages such as increasing power and decreasing metabolism. In most of active prosthesis in order to create a movement or increase the force at the push-off, electrical actuators are used like a motor. In cases where a higher-power motor is necessary, the capacity, weight and using electricity in motor become increased, which causes problem for people with an amputation. This research is conducted to optimize ankle prosthesis with use of an active alignment which is made by experts. In this prosthesis to reduce the motor power, a passive element of spring is used in order to save energy while walking and release it in push-off. After setting spring position in the prosthesis, the dynamic and kinematic analysis are done and eventually the amount of used force in both modes of spring and non-spring would be compared. The results show that the presence of spring in the selected mechanism would cause motor to perform force increase and power reduction to mechanism at the push-off phase.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Ankle-Foot Prosthesis Prototype with Extended Push-Off

Current commercially available prosthetic feet have succeeded in decreasing the metabolic cost and increasing the speed of walking compared to walking with conventional, mostly solid prosthetic feet. However, there is still a large discrepancy when compared with a non‐disabled gait, and the walking pattern remains strongly disturbed. During the stance phase of the leg, t...

متن کامل

Active control of a powered ankle-foot prosthesis

Amputees suffer a higher metabolic demand on their bodies. Passive prostheses seek to reduce this deficit through elastic distribution of the energy inherently dissipated in walking. Yet with no capacity to generate torque they lack truly biomimetic function. The active prosthesis is a solution to this and opens up a world of active control in the timing and magnitude of energy return. Being ab...

متن کامل

Ankle-knee prosthesis with active ankle and energy transfer: Development of the CYBERLEGs Alpha-Prosthesis

This paper presents the development of the CYBERLEGs Alpha-Prototype prosthesis, a new transfemoral prosthesis incorporating a new variable stiffness ankle actuator based on the MACCEPA architecture, a passive knee with two locking mechanisms, and an energy transfer mechanism that harvests negative work from the knee and delivers it to the ankle to assist pushoff. The CYBERLEGs Alpha-Prosthesis...

متن کامل

A Novel Design Approach and Operational Strategy for an Active Ankle-Foot Prosthesis

1 Introduction In order to enable lower limb amputees to regain natural and versatile walking patterns, the development of active ankle-foot prostheses is required. During locomotion, above-knee amputees show a lower walking speed for keeping the energy effort in the range of non-amputee walking [2]. To avoid this, prostheses with adaptable characteristics and the possibility to store and reuse...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 2

صفحات  48- 55

تاریخ انتشار 2017-07-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023