P-170: Zinc and Copper Serum Level Alterations after An Intra Uterine Device Insertion

نویسندگان

چکیده مقاله:

Background: Intra uterine devices (IUDs) are among the most commonly used contraception methods around the world. The most common form of IUDs used in Iran, is IUD Copper T-380A. As recently there is great emphasis on the role of blood zinc levels on general health conditions, this study was performed to assess the effects of IUD T-380-A insertion on zinc and also copper serum levels. Materials and Methods: This was a prospective cohort study performed on 66 women clients attending Health Centers of Tehran. After giving adequate explanations about the study and obtaining the clients’ written consent, a blood sample was obtained before and 3 months after the insertion of a Copper T-380-A IUD, and serum levels of copper and zinc were measured by an auto analyzer Instrument in a single laboratory. None of the participants were anemic, and so none received ferroussulfate complements during the study. The statistical software and methods used were: SPSS version 16 and paired sample t tests. P<0.05 were considered significant. Results: There were significant elevations in both copper (166.70 ± 32.31 vs. 153.74 ± 39.29 μg/dl) and zinc (105.47 ± 16.13 vs. 90.76 ± 16.22 μg/dl) mean serum levels, 3 months after IUD insertion. Conclusion: In this study, there was a slight increase in copper serum levels- but not reaching toxic levelsafter IUD insertion, which was expectable, as the IUDs contained copper. As zinc has an inverse relationship with copper in the body, the excess of copper can be a concern. In this study this concern was removed, due to not the decrease, but the remarkable increase of serum zinc levels after IUD insertion. This finding needs further investigations in larger studies with different study settings, to evaluate the exact health risks or benefits of IUDs.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Copper and zinc concentrations in the uterine fluid and blood serum during the bovine estrous cycle

To investigate uterine and serum copper (Cu) and zinc (Zn) concentrations variation during the bovine estrus cycle , 232 blood and genital tract samples were collected from the abattoir in Urmia. The phase of the estrous cycle was determined by the examination of the ovaries and the uterine tonicity. Of the 46 samples selected for use in the study, 13 were pro-estrus, 10 estrus, 8 metestrus, an...

متن کامل

Uterine perforation by the intra-uterine device.

The article presents 5 cases of IUD translocation in women aged 27-34; 3 of the devices were Copper-7; the others were a Copper-T and Lippes Loop. In all cases the devices' strings were missing and the devices had been localized through X-rays and sometimes through a hystero-salpingogram. The devices were removed by laparoscopy in 3 cases, and by laparotomy in 2 cases. IUD translocation is u...

متن کامل

Forgotten Migrated Intra-Uterine Contraceptive Device and its rare complication rare case report from Kashmir Valley

The intra-uterine device (Copper T) has been widely used as contraceptive method since 1965. Due to its low cost, effective and reversible nature and long-term benefits, it is widely being used in the developing world. The intra-uterine contraceptive device (IUCD) has been linked to complications like bleeding, perforation and migration to other surrounding organs. The intra-abdomen migration o...

متن کامل

Uterine perforation by the multiload CU250 intra-uterine device.

A case of perforation of the uterus by the Multiload Cu250 IUD in a 28 year old Malay woman is presented. The Multiload Cu250 is a newer device, introduced in 1974, and the mode of insertion (withdrawal) makes perforation with this IUD unlikely and to date no such case had been reported. The patient, para 3, had a period of amenorrhea of 7 weeks. A menstrual regulation procedure was performe...

متن کامل

The effect of an intra-uterine device on uterine motility in women and rhesus monkeys.

PRESENT understanding of human female reproductive physiology has largely been derived from the results of animal experimentation, and particularly from studies on the rhesus monkey. This is also true of our present knowledge of the possible modes of action of an intra-uterine device (IUD). Recent studies in the rhesus monkey have shown that an intra-uterine device is contraceptive in this spec...

متن کامل

Copper and zinc concentrations in the uterine fluid and blood serum during the bovine estrous cycle

To investigate uterine and serum copper (Cu) and zinc (Zn) concentrations variation during the bovine estrus cycle , 232 blood and genital tract samples were collected from the abattoir in Urmia. The phase of the estrous cycle was determined by the examination of the ovaries and the uterine tonicity. Of the 46 samples selected for use in the study, 13 were pro-estrus, 10 estrus, 8 metestrus, an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 6  شماره 2

صفحات  -

تاریخ انتشار 2012-09-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023