Power filtering method with controllable inductance for eliminating thyristor rectifier load harmonics

نویسندگان

  • Barati, Hassan Department of Electrical Engineering, Dezful Branch, Islamic Azad University, Dezful, Iran
  • Daneshi, Farhad Department of Electrical Engineering, Ahvaz Branch, Islamic Azad University, Ahvaz, Iran
چکیده مقاله:

In this paper, we propose a Controlled Inductance Power Filter (CIPF) to solve power quality problems in industrial DC power supply systems. This method is based on the theory of magnetic potential equilibrium combined with active hybrid filter technology. Initially the system structure and filter wiring scheme are presented and the equivalent circuit is performed with the mathematical models of the filtering system. Then, a refined control strategy is designed to achieve better filtering performance.  Technical features such as the elimination of harmonics caused by nonlinear loads and the attenuation are illustrated by the analysis mechanism. Also, the stability of the system based on the NYQUIST criterion is discussed and finally the simulation model of the filtering system is implemented in the Simulink environment of MATLAB software. The simulation results confirm the theory of path analysis and show that the proposed method with proper control gain can effectively eliminate the harmonics passing through the transformer and improve the efficiency of the rectifier system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eliminating harmonics from the facility power system

odically occur in a facility’s electrical system can cause equipment malfunction, data distortion, transformer and motor insulation failure, overheating of neutral buses, nusiance tripping of circuit breakers, and solid-state component breakdown. The cost of power quality problems can be enormous. Equipment replacement can cost tens of thousands of dollars. Downtime, however, can run in the mil...

متن کامل

Reactive Compensation Capability Of Fixed Capacitor Thyristor Controlled Reactor For Load Power Factor Improvement: A Review

Reactive power compensation capability of a fixed capacitor thyristor controlled reactor type static VAr compensator is being investigated in this paper. The TCR has the power transfer controlling capability only in the lagging power factor range. The range of TCR can be extended by connecting a fixed capacitor in shunt with the TCR. The compensated reactive power can be selectively controlled ...

متن کامل

Applying Optimal Sliding Mode Based Load-Frequency Control in Power Systems with Controllable Hydro Power Plants

In this paper an optimal load-frequency controller for a nonlinear power system is proposed. The mathematical model of the power system consists of one area with several power plants, a few concentrated loads and a transmission network, along with simplified models of the neighbouring areas. Firstly, a substitute linear model is derived, with its parameters being identified from the responses o...

متن کامل

Comprehensive Analysis of Dense Point Cloud Filtering Algorithm for Eliminating Non-Ground Features

Point cloud and LiDAR Filtering is removing non-ground features from digital surface model (DSM) and reaching the bare earth and DTM extraction. Various methods have been proposed by different researchers to distinguish between ground and non- ground in points cloud and LiDAR data. Most fully automated methods have a common disadvantage, and they are only effective for a particular type of surf...

متن کامل

Design and Control of a Novel hybrid Active Power Filter based on Load Harmonic Currents Separation with the aim of DC-link voltage minimization in voltage source converter

This paper proposes a new hybrid active power filter, including voltage source converter (VSC) based active power filter and Thyristor Controllable LC Passive Filter (TCLC-HAPF) for eliminating harmonic load current components and compensating reactive power. This new structure which is based on the separation of high and low-frequency components of load current idea can reduce the drawbacks of...

متن کامل

Efficient Load Scheduling Method For Power Management

An efficient load scheduling method to meet varying power supply needs is presented in this paper. At peak load times, the power generation system fails due to its instability. Traditionally we use load shedding process. In load shedding process disconnect the unnecessary and extra loads. The proposed method overcomes this problem by scheduling the load based on the requirement. Artificial neur...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 9  شماره 1

صفحات  11- 17

تاریخ انتشار 2020-05

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023