Quality assurance prusedore in high dose rate bracythrapy

نویسندگان

  • Ali Jabbari arfaei Tajrish Shohada Hospital, Tehran, Iran.
  • Ali Rajabi Secondary Standard Dosimetry Laboratory (SSDL), Pars isotope Co., Karaj, Iran.
  • Mohsen bakhshandeh Associate Professor, Radiology Technology Department, Allied Medical Faculty, Shahid Beheshti University of Medical Science,Tehran, Iran
چکیده مقاله:

Introduction: Quality assurance is essential for obtaining the best achievable tumor control, avoiding unnecessary side effects, accuracy and safety during performing High Dose Rate (HDR) Brachytherapy (BT). Quality assurance is extremely important because HDR BT procedures are performed quickly, with high doses given in a short time period, with little opportunity for correction. The quality assurance procedure can be divided into the four categories: Treatment unit, Treatment Planning System (TPS), Imaging and Patient treatment procedure. These categories include different tests which should to be done periodically in order to verify the accurate treatment. In this study a number of important quality assurance tests were performed.   Materials and Methods: Physical and Safety parameters of the Sagi Nova (Eckert & Ziegler Bebig GmbH) machine with Co-60 source was investigated. Determination of source position accuracy was done in two methods 1) video-ruler source position and 2) Gafchromic film with posi check phantom (PTW, Germany). Reference Air Kerma Strength (RAKS) of the source was measured according to IAEA TECDOC-1274 using a well-type ionization chamber (PTW, Germany) with suitable holder for insertion of the afterloader's catheter. Another physical parameter like Length of treatment tubes, Transit time, Timer consistency and Timer linearity were measured. Safety parameters like Communication equipment, Applicator attachment, Catheter attachment lock, Door interlock, warning lights, Room monitor, Hand held monitor, Treatment interrupt, and Emergency stop were evaluated.   Results: All items related to safety parameters investigated and defects have been resolved. Source positioning accuracy in both video-ruler and Gafchromic measurement showed a difference of less than one millimeter. RAKR measured by the well-type ionization chamber in comparison with the input value in the TPS showed a 0.5% difference which is acceptable.   Conclusion: Quality assurance of Sagi Nova HDR BT machine was performed. Physical and Safety parameters were investigated. The measurements showed acceptable results. Because of the high importance of HDR BT treatment, it is recommended each center perform quality assurance tests according to the existing protocols in the regular time interval.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High dose rate (HDR) brachytherapy quality assurance: a practical guide

The widespread adoption of high dose rate brachytherapy with its inherent dangers necessitates adoption of appropriate quality assurance measures to minimize risks to both patients and medical staff. This paper is aimed at assisting someone who is establishing a new program or revising one already in place into adhere to the recently issued Nuclear Regulatory Commission (USA) regulations and th...

متن کامل

Quality assurance measurements for high‐dose‐rate brachytherapy without film

The purpose of this study was to develop new and modified tools that allow HDR brachytherapy quality assurance tests to be carried out efficiently without film, video cameras, stopwatches, and mechanical rulers; and to devise methods that use these new tools for daily and quarterly check procedures, which are efficient and provide increased accuracy compared to previous methods. The HDR brachyt...

متن کامل

A Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy

Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...

متن کامل

The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.

PURPOSE High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2...

متن کامل

Usefulness of direct‐conversion flat‐panel detector system as a quality assurance tool for high‐dose‐rate 192Ir source

The routine quality assurance (QA) procedure for a high-dose-rate (HDR) 192Ir radioactive source is an important task to provide appropriate brachytherapy. Traditionally, it has been difficult to obtain good quality images using the 192Ir source due to irradiation from the high-energy gamma rays. However, a direct-conversion flat-panel detector (d-FPD) has made it possible to confirm the locali...

متن کامل

Effects of dose scaling on delivery quality assurance in tomotherapy

Delivery quality assurance (DQA) of tomotherapy plans is routinely performed with silver halide film which has a limited range due to the effects of saturation. DQA plans with dose values exceeding this limit require the dose of the entire plan to be scaled downward if film is used, to evaluate the dose distribution in two dimensions. The potential loss of fidelity between scaled and unscaled D...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  285- 285

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023