Radiobiological and physical effects of patient setup errors during whole breast irradiation

نویسندگان

  • M.J. Kim Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
  • M.Y. Lee Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
  • S.H. Park Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
  • S.R. Lee Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
  • T.S. Suh Department of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, Korea
چکیده مقاله:

Background: The dose-related effects of patient setup errors on bio-physical indices were evaluated for the conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques (WBI). Materials and Methods: The treatment plans of 10 patients receiving left WBI were retrospectively selected for evaluation. The bio-physical effects of dose variations were evaluated by shifting the isocenters and gantry-angles of the treatment plans. Dose-volume histograms of the planning target volume (PTV), heart, and lungs were generated, and the conformity index (CI), homogeneity index (HI), tumor control probability (TCP), and normal tissue complication probability (NTCP) were determined. Results: The D95 of the PTV for an &ldquo;isocenter shift plan&rdquo; with a posterior direction decreased by approximately 15%, and the TCP of the PTV decreased by approximately 50% for the FIF technique and by 40% for the CW; however, the NTCPs of the lungs and heart increased for both techniques. Increasing the gantry-angle decreased the TCPs of the PTV by 24.4% (CW) and by 34% (FIF). The NTCPs of the lungs and heart for the two techniques differed by only 3%. The CIs and HIs for the CW case were higher than the corresponding values obtained for the FIF case. Significant differences were observed between the two techniques (p<0.01). Conclusion: Our results revealed that the biophysical properties of the FIF case were more sensitive to setup errors than those in the CW case. The radiobiological-based analysis could be detected significant dosimetric errors and provided a practical patient quality assurance method for guiding the bio-physical effects. &nbsp;

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Setup Errors on Dose Distribution for Tangential Wedge Field and Field-in-Field Techniques During Breast Irradiation

This study is aimed to evaluate the effects of setup errors on dose distribution for target volume and healthy tissue within the irradiated volume and also critical surrounding organs for breast radiotherapy (RT) using both the tangential field and the field-in-field (FIF) technique. Ten patients with breast cancer were enrolled. For each patients two plans were generated; tangential field plan...

متن کامل

Evaluation of changes in excision cavity volume during whole breast irradiation using secondary CT image

Background: The aim of this study was to evaluate the reduction in excision cavity volume (ECV) during the whole breast radiotherapy (WBRT). The delineating of reduced cavity volume on secondary CT (computed tomography) might decrease the field size of boost plan. Materials and Methods: Twenty patients were treated having breast conservative surgery. At first, primary CT simulation (CT-1) was d...

متن کامل

Dosimetric and radiobiological evaluation of Accelerated Partial Breast Irradiation Techniques

Accelerated Partial Breast Irradiation (APBI) decreases the duration of entire radiotherapy course (Sanders ME et al 2007). The reduced treatment volume makes APBI more appealing to both clinicians and patients. The uses of brachytherapy either as HDR or LDR interstitial implants have shown promising results which are obvious from the published research works (Arthur DW et al 2003; Baglan KL et...

متن کامل

Radiobiological principles in intravascular irradiation.

BACKGROUND There is wide interest in the use of intravascular irradiation to control restenosis following balloon angioplasty. Part of the mechanism of restenosis appears to be the proliferation of smooth muscle cells (SMCs), triggered to divide by the damage caused by the angioplasty, and this proliferation can be inhibited by irradiation with y-rays or beta-rays. METHODS In vitro data for t...

متن کامل

evaluation of changes in excision cavity volume during whole breast irradiation using secondary ct image

background: the aim of this study was to evaluate the reduction in excision cavity volume (ecv) during the whole breast radiotherapy (wbrt). the delineating of reduced cavity volume on secondary ct (computed tomography) might decrease the field size of boost plan. materials and methods: twenty patients were treated having breast conservative surgery. at first, primary ct simulation (ct-1) was d...

متن کامل

Evaluation of regional nodes irradiation during breast cancer radiotherapy

Background: The purpose of this study was to evaluate nodal irradiation with conventional three-field's technique. Materials and Methods: Fifty patients with breast cancer were enrolled in this study. Computed tomography scans in the supine treatment position were imported into a treatment planning system. Levels I-III axillary and supraclavicular nodes were identified and their depths to the a...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره None

صفحات  343- 352

تاریخ انتشار 2017-10

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023