Relative brightness due to temperature changes with ultrasound image analysis during Radiofrequency ablation

نویسندگان

  • Atusa Montaseri Master of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Iran.
  • Manijeh Mokhtari Dizaji Professor of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Iran
  • Zeinab alsadat Ahmadi Ph.D. Student of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Iran
چکیده مقاله:

Introduction: Diagnosis of primary and secondary cancers to treat patients with diffuse and malignant tumors is an important subject. The appropriate treatment will be eliminating primary and metastatic tumors. Radiofrequency ablation with localized heat induction in the target tissue causes irreversible cellular damage and tissue coagulation. Estimation of tissue temperature changes is carried out under the guidance of ultrasound system. In addition to parameters such as variation in attenuation coefficient, acoustic power, thermal expansion, and variation in sound speed, the brightness of the ultrasound image shows a clear change in temperature. The aim of this study was to change brightness of ultrasound images in order to evaluate the thermal variations of tissue by Radiofrequency method. Materials and Methods: With the fixation of ultrasound probe on the target tissue, all transverse cross- sectional images are visible from tip of the Radiofrequency electrodes and thermal sensor. DICOM images were transferred to PC and analyzed with RADWORKS Diagnostic 5.1 software. In order to estimate brightness of images for every degree temperature variation, ROI was plotted in desired areas, and average brightness values in pixels were assessed as a parameter without unit. In ultrasonic image processing, Circular ROIs was placed on both sides of thermal sensor, dimensions of each window were 2000 pixels (size of each pixel 0.05mm). To evaluation relative brightness, increasing temperature from 22˚C to 70 ˚C and reducing the temperature from 70 to 30 ˚C on reference image (with 22 ˚C) was drawn.  Results: brightness value for each temperature was normalized to mean brightness of reference image and relative brightness variation was calculated. Results for each temperature were calculated as mean and standard deviation with descriptive analysis. Then, to verify the correlation between brightness and temperature variations, Pearson correlation analysis was performed with 95% confidence. As temperature rises, relative brightness parameter increased linearly (R> 0.99 and P<< 0.005) with cooling tissue, slop of brightness images decreased faster in linear phase of 22 to 50 ˚C (R> 0.98). During heating of the tissue at 22 ˚C until 60 ˚C for every 13 ˚C, relative brightness increased by 25%. Then temperature range from 60 to 63 ˚C was quickly achieved maximum value. In cooling stage, until the temperature reaches 30 ˚C, it continued with 25% steps per 7 ˚C reduction of temperature. At 35 -33 ˚C, it has reached -50% and -52% of the initial value. Conclusion: In this study, not only brightness of Ultrasound images can be used as a qualitative measure of tissue thermal variations but also it can be provided as a quantitative map of brightness variation during Radiofrequency ablatio

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

an investigation of brightness changes in ultrasound images due to temperature variations in liver tissue during radiofrequency ablation

introduction: one of the minimally invasive methods of treatmenting liver malignancies is radiofrequency ablation (rfa) which can be applied to primary or secondary tumors. nevertheless, the disease recurrence is probable after rfa application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. the goal of this work was t...

متن کامل

Adaptive ultrasound temperature imaging for monitoring radiofrequency ablation

Radiofrequency ablation (RFA) has been widely used as an alternative treatment modality for liver tumors. Monitoring the temperature distribution in the tissue during RFA is required to assess the thermal dosage. Ultrasound temperature imaging based on the detection of echo time shifts has received the most attention in the past decade. The coefficient k, connecting the temperature change and t...

متن کامل

Temperature Controlled Radiofrequency Ablation

Since its introduction in 1987, radiofrequency (RF) ablation has developed to become the treatment of choice for symptoms caused by atrio ventricular (AV) reentrant tachycardia, isthmus related atrial flutter, AV-nodal reentrant tachycardia and to some extent also for certain types of ventricular tachycardias. The introduction of new cardiac activation mapping systems has further contributed to...

متن کامل

Monitoring radiofrequency ablation with ultrasound Nakagami imaging.

PURPOSE Radiofrequency ablation (RFA) is a widely used alternative modality in the treatment of liver tumors. Ultrasound B-mode imaging is an important tool to guide the insertion of the RFA electrode into the tissue. However, it is difficult to visualize the ablation zone because RFA induces the shadow effect in a B-scan. Based on the randomness of ultrasonic backscattering, this study propose...

متن کامل

Dynamic frame selection for in vivo ultrasound temperature estimation during radiofrequency ablation.

Minimally invasive therapies such as radiofrequency ablation have been developed to treat cancers of the liver, prostate and kidney without invasive surgery. Prior work has demonstrated that ultrasound echo shifts due to temperature changes can be utilized to track the temperature distribution in real time. In this paper, a motion compensation algorithm is evaluated to reduce the impact of card...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  421- 421

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023