Saving Energy by Exergetic Analysis of MTP Process Refrigeration System

نویسندگان

  • Masoud Beheshti Department of Chemical Engineering, University of Isfahan, Isfahan, Iran
چکیده مقاله:

The exergetic analysis is a tool that has been used successfully in many studies aiming a more rational energy consumption to reduce the cost of processes. With this analysis, it is possible to perform an evaluation of the overall process, locating and quantifying the degradation of exergy. This paper applies exergy approach for analyzing the heat exchanger network design and refrigeration of MTP process. For this purpose, the behavior of some industrial processes and refrigeration cycle with propylene refrigerant has been investigated by exergy method. The equations of exergy destruction and exergetic efficiency for main components such as compressors, heat exchangers and expansion valves were studied. A specified section of propylene recovery unit with its refrigeration cycle has been simulated to perform the exergy analysis. Adding a new valve with optimum pressure drop according to process constraints and an expander results in high performance of multi-stream heat exchanger, saving cold utility consumption, using excess heat of the process section, and low required compression power (in the refrigeration section) which are the most important characteristics of the proposed configuration. Results show that the annual profit reaches 4.3 %.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Study and Energy Saving Process Analysis of Hybrid Absorption-Compression Refrigeration Cycles

In an attempt to improve the performance of hybrid absorption and mechanical vapor compression refrigeration systems and to determine the fundamental reasons for such improvements, two configurations of the hybrid refrigeration cycle with a booster compressor at different positions of the cycle (between the evaporation and the absorber, or between the generator and the condenser) are simulated ...

متن کامل

advanced exergetic analysis of a refrigeration system for liquefaction of natural gas

during the last years the total cost of lng technology has decreased significantly due to improvements of the liquefaction process. however, many liquefaction plants that are still in operation use a three-cascade refrigeration system. in this paper, an advanced exergetic analysis is applied to better understand the operation of a three-cascade refrigeration system for liquefaction of natural g...

متن کامل

Energetic and Exergetic Analysis of Internal Combustion Engine Cogeneration System

In this article, the first and second law analysis of diesel engine based cogeneration system was performed. Fuel utilization efficiency, rate of power, and rate of process heat of the plant were determined and various efficiencies based on both energy and exergy methods and the performance assessment parameters are defined for both the system components and the entire cogeneration plant. The o...

متن کامل

Energetic and Exergetic Analysis of an Ejector-Expansion Refrigeration Cycle Using the Working Fluid R32

The performance characteristics of an ejector-expansion refrigeration cycle (EEC) using R32 have been investigated in comparison with that using R134a. The coefficient of performance (COP), the exergy destruction, the exergy efficiency and the suction nozzle pressure drop (SNPD) are discussed. The results show that the application of an ejector instead of a throttle valve in R32 cycle decreases...

متن کامل

Energetic and Exergetic Analysis of a Transcritical N2O Refrigeration Cycle with an Expander

Comparative energy and exergy investigations are reported for a transcritical N2O refrigeration cycle with a throttling valve or with an expander when the gas cooler exit temperature varies from 30 to 55 ◦C and the evaporating temperature varies from −40 to 10 ◦C. The system performance is also compared with that of similar cycles using CO2. Results show that the N2O expander cycle exhibits a l...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 5  شماره 1

صفحات  43- 54

تاریخ انتشار 2017-11-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023