Seismic Performance of Low-Ductility Precast Wall Structure with Base Isolation

نویسندگان

  • Azlan Adnan Faculty of Civil Engineering, Universiti Teknologi Malaysia
چکیده مقاله:

It is impractical and uneconomic to design a structure that remains elastic throughout severe ground motions. The main design philosophy is that minor structural damages are acceptable as long as the structure does not collapse. Hence, seismic base isolation of structures provides a better alternative in constructing seismic resistant structures. A fixed-base structure designed in accordance to seismic code provisions would be more prone to damage than their seismic isolation counterparts. This paper presents finite element analyses carried out to investigate the feasibility of applying locally produced elastomeric rubber bearing base isolators in seismically isolating non-ductile precast concrete structures from earthquake excitations. The precast wall structures were analyzed in terms of in-plane and out-of-plane isolation effects due to dynamic lateral loads. Ground excitations from three classifications of acceleration history based on different a/v ratios were used in dynamic analyses of the structures. The results showed that although the base isolator had successfully reduced most of the critical structural responses, it also compromised some other less crucial seismic behaviour of the structures. Current design philosophy for seismic base isolation should be urgently revisited. Imperative discussion and review of the feasibility in utilizing base isolators as seismic mitigation plan for seismic prone areas are presented.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Design Considerations for Precast Concrete Shear Wall Connections

The performance of precast shear wall panel structures subjected to earthquakes relies on the behaviour and integrity of the connections between the panels. The current lack of knowledge on the seismic behaviour of precast wall connections limits the use of such systems in earthquake areas. This paper presents results of an extensive experimental program undertaken at the University of Manitoba...

متن کامل

Study on Metering Scheme of Seismic Experiment for Shear Wall Built with Precast Hollow Slab

Abstract: Shear deformation is the most principal deformation in the lateral deformation of shear wall built with precast hollow slab which is designed to be strong shearing and weak bending. The special mechanical characteristic of the shear wall is the relative deformation of the concrete on both sides of vertical and inner joint respectively. The study introduces the measuring scheme of shea...

متن کامل

Seismic Response Control Using Base Isolation Strategy

Earthquakes are one of the natural hazards that occur due to sudden violent movement of earth’s surface which releases energy and has destructive power in many parts of the world. The development of recent technologies for the control of seismic hazards catches the attention of structural engineers to make the structures seismically resistant. The seismic base isolation technique is a passive p...

متن کامل

Nonlinear Dynamic Analysis of a Structure with a Friction-Based Seismic Base Isolation System

The seismic activity in some parts of the world requires that the performance of structures under this type of excitation, is carefully evaluated. In regions where seismicity is insignificant, the conventional design approach aims at the design of structural members in such a way that all static and dynamic loads (such as wind load) are withstood elastically. However, in cases where seismic exc...

متن کامل

Pillow-Shape Base Isolation System and Its Seismic Behavior

In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...

متن کامل

Investigation and Analysis of Empirical Field Seismic Damage to Bottom Frame Seismic Wall Masonry Structure

To understand the seismic damage characteristics of bottom frame-wall buildings and to study their seismic performance, the seismic damage outcomes of  bottom frame-wall structures in Du jiang weir by the Wen chuan earthquake on May 12,2008, China were field observed and studied. The assesment of the seismic damage to the bottom frame-wall masonry in Du jiang weir urban showed that the damage t...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 26  شماره 2

صفحات  153- 162

تاریخ انتشار 2013-02-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023