Small field size dose-profile measurements: A comparison between Eclipse™ treatment planning system with NIPAM polymer gel dosimeter dose measurement

نویسندگان

  • Seyed Mohammad Mahdi Abtahi Physics Department, Imam Khomeini International University, Qazvin, Iran, Tel: +98-28-33901345, Fax: +98-28-33780040; [email protected]; [email protected]
  • Vahid Anaraki Medical Radiation Department, Islamic Azad University, Science and Research Branch, Tehran, Iran.
چکیده مقاله:

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condition is volume averaging. The aim of this study was to investigate dose distribution for small field sizes using NIPAM polymer gel dosimeter through MRI technique. Materials and Methods: NIPAM polymer gel production: To fabricate NIPAM gel dosimeter at first, the gelatin (5 wt %) completely dissolved in 90% (80.1 wt %) of the water at 50 °C. Approximately 3 wt. % of Bis was dissolved at 50 °C. The N-isopropylacrylamide (3 wt%) was added after the gelatin–cross linker mixture was cooled to almost 37 °C. THPC (10 mM), as the antioxidant, was mixed with the %10 remnants of water, and was added to the solution. After preparation, the gel tubes were stored at temperature of 4- 7 °C in a refrigerator for 12 h. Irradiation: Irradiation experiments were performed by a 6 MV X‑rays generated by a 2100C/D Varian linac. The vials filled with calibration NIPAM gel dosimeters were positioned fixedly in floor a 20×20×15 cm3 water phantom. Also, 5 cm Perspex slab was placed under the water phantom to ensure a full photon scattering condition. For small field investigating a Perspex cubic phantom with dimensions of 7×7×7 cm3 filled with NIPAM polymer gel dosimeter. The phantom was irradiated using three perpendicular field with size of 1×1 cm2. Response readout: The response of NIPAM polymer gel dosimeter was readout using a 1.5 T MRI scanner (Siemens Avanto, Germany). To scan the polymer gels a 32-echo Carr-Purcel-Meiboom-Gill (CPMG) pulse sequence was applied. Results: Calibration curve of NIPAM polymer gel dosimeter was obtained. Equation (1) represents the variation of the R2 of the NIPAM polymer gel dosimeter a function of absorbed dose. R2=0.208×Dose+1.925                                                                   (1) Radiation dose profile in depth of 35 mm in NIPAM polymer gel dosimeter was compared with that calculated using Eclipse™ treatment planning system. Conclusion: Results confirmed an accordance between dose profiles measured using polymer gel dosimeter and that calculated by TPS. Results showed a maximum difference of 3.8% between dose profiles calculated using TPS and measured by polymer gel dosimeter.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small field size dose-profile measurements using MAGIC- f polymer gel dosimeter and EBT3 film dosimeter

Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...

متن کامل

Dose integration and dose rate characteristics of a NiPAM polymer gel MRI dosimeter system

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

متن کامل

Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

متن کامل

Dose response evaluation of a low density anoxic polymer gel dosimeter using MRI

Background: The human body contains of different tissues and cavities with different physical and radiological properties. Most important among these are tissues and cavities that are radiologically different from water, including lungs, sinuses and bones. Gel dosimetry provides a unique feature to display dose distributions occurring in clinical radiation therapy in three dimensions. Materials...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

Effect of gold nanoparticles on dose enhancement of 6 Mv X-rayin MAGIC_f polymer gel dosimeter

Introduction: Currently, the potential application of gold nanoparticles (AuNPs) to increase the efficiency of radiation therapy have been investigated. However, the loss of an appropriate method to estimate the dose distribution in nanoparticle laden tissue limits the applicability of nanoparticles in radiotherapy clinics. Polymer gel dosimetry provides an accurate and precise...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 15  شماره Special Issue-12th. Iranian Congress of Medical Physics

صفحات  139- 139

تاریخ انتشار 2018-12-01

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023