Stress analysis of all-ceramic three-unit dental bridges ‌using finite element method

نویسندگان

  • Biria, Mohammad jafar
  • Eslami Amirabadi, Gholam reza
  • Farahmand, Farzam
چکیده مقاله:

Stress analysis of all-ceramic three-unit dental bridges ‌using finite element method M.F. Biria *- Dr. F. Farahmand** - Dr. Gh. Eslami Amirabadi*** *- M.S in Biomechanics Engineering Faculty of Mechanics. Sharif Industrial University. ** - Associate professor of Mecanical Engineering Dept. Sharif Industrial University. *** - Assistant professor of Orthodontics Dept. Faculty of Dentistry Shahed University of Medical Sciences. Background and aim: Mechanical fracture is a common cause for the failure of three-unit dental bridges, particularly the all-ceramic ones. The goal of the present study was to evaluate the effects of convergent angles of the abutments on the peak and distribution of mechanical stresses wihtin the prosthesis and at the restoration abutment interface of a three-unit all-ceramic bridge using finite element method. Materials and Methods: The cloud points of three-D geometrical data of the second premolar and first and second molar teeth were obtaind using ATOS Scanner system and utilized for the reconstruction of a surface model of the three-unit bridge in CATIA software. Data were than transferred to I-DEAS software for mesh generation and finite element analysis. Two EF models were developed with convergent angles corresponding to the up and low defined range including 171900 and 168700 tetraherdal solid four-node elements, respectively. The models were subjected to two different prosthesis materials and three different load cases. Results: The maximum tensile stresses occured on the gingival surface of the second premolar retainer and at the tooth /restoration interface on the marginal distal surface of the second molar abutment. The peak tensile stress was relatively lower for the model with the higher convergent angle but the difference was not significant. Changing the prosthesis material from IE2 to Dicor desreased the stresses within the prosthesis. Conclusion: Higher safety factor was found for IE2 due to its higher mechanical strenght. Moreover, it was proved that load condition played an important role on the mechanical stress observed. Key Words: Prosthesis - Three unit bridge - Finite Element Method - Convergence angles. ‌

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite element analysis of three- and four-unit bridges.

A two-dimensional finite element model of a mandibular quadrant was used to examine differences in magnitude of the principal stresses from the placement of three- and four-unit bridges. The area of interest spanned the first premolar to the second molar. Loading conditions were (i) vertical and distributed and (ii) 30 degrees to the vertical and concentrated. The principal stresses were calcul...

متن کامل

Strength analysis of a three-unit dental bridge framework with the Finite Element Method.

PURPOSE The aim of the study was to analyse the strength of a prosthetic bridge with variable geometry in the connectors between the span and the retention elements on the pillar teeth crowns. METHODS Research was carried using the Finite Elements Method (FEM) on a model of the bridge in the anterior teeth arch in the field 21-22-23, obtained using a contact scanner and computer aided design ...

متن کامل

effect of abutment taper on the fracture resistance of all-ceramic three-unit bridges

statement of problem: the connector area is the weakest zone of an all-ceramic fixed partial denture (fpd), where most catastrophic failures of the prostheses tend to occur. purpose: the aim of the present study was to assess the effect of the convergence angle of abutments on the fracture resistance of three-unit fixed partial dentures made of ips-empress2. materials and methods: forty extract...

متن کامل

buckling of viscoelastic composite plates using the finite strip method

در سال های اخیر، تقاضای استفاده از تئوری خطی ویسکوالاستیسیته بیشتر شده است. با افزایش استفاده از کامپوزیت های پیشرفته در صنایع هوایی و همچنین استفاده روزافزون از مواد پلیمری، اهمیت روش های دقیق طراحی و تحلیل چنین ساختارهایی بیشتر شده است. این مواد جدید از خودشان رفتارهای مکانیکی ارائه می دهند که با تئوری های الاستیسیته و ویسکوزیته، نمی توان آن ها را توصیف کرد. این مواد، خواص ویسکوالاستیک دارند....

Correcting the stress-strain curve in hot compression test using finite element analysis and Taguchi method

In the hot compression test friction has a detrimental influence on the flow stress through the process and therefore, correcting the deformation curve for real behavior is very important for both researchers and engineers. In this study, a series of compression tests were simulated using Abaqus software. In this study, it has been employed the Taguchi method to design experiments by the factor...

متن کامل

Three-Dimensional Finite Element Analysis of Anterior Two-Unit Cantilever Resin-Bonded Fixed Dental Prostheses

The aim of this study was to evaluate the influence of different framework materials on biomechanical behaviour of anterior two-unit cantilever resin-bonded fixed dental prostheses (RBFDPs). A three-dimensional finite element model of a two-unit cantilever RBFDP replacing a maxillary lateral incisor was created. Five framework materials were evaluated: direct fibre-reinforced composite (FRC-Z25...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 16  شماره 4

صفحات  35- 43

تاریخ انتشار 2004-07