The feasibility of using microstrip gas detector as radon detector for earthquake prediction

نویسندگان

چکیده مقاله:

In the last decade, several studies have concluded that elevated concentrations of radon gas in soil or groundwater could be the sign of an imminent earthquake. It is believed that in case of sudden movement of rocks before earthquake, radon is released from the depth of ground and reached the surface. In this way, by measuring Radon concentration change, earthquake prediction is possible. In this study, for the purpose of the feasibility of using microstrip gas detector in monitoring Radon change, initially for the verification of the code, the range of radon alpha particles and its progeny in the air has been obtained in the standard condition, which is consistent with the experimental results. Then detector geometry has been simulated by MCNPX code and after examining the average of detector response to decay, the output code is calibrated considering the information about the radon changes in Jowshan hot spring. The results have shown that the detector response is comparable to the experimental data and can be used as an earthquake pre-indicator.  

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The gas proportional scintillation counter / microstrip gas chamber hybrid detector

The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...

متن کامل

An Evidence Based Earthquake Detector using Twitter

This paper presents a notification system to identify earthquakes from firsthand reports published on Twitter. Tweets from target regions in Australia and New Zealand are checked for earthquake keyword frequency bursts and then processed to identify evidence of an earthquake. The benefit of our earthquake detector is that it relies on evidence of firsthand ‘felt’ reports from Twitter, provides ...

متن کامل

شبیه سازی یک آشکارساز تناسبی میکرو نواری برای آشکارسازی گاز رادن و دختران با کد مونت کارلو (MCNPX)

Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...

متن کامل

Investigating Indoor Radon Concentration Using CR-39 Detector; a Case Study of Gachin Dwellings in Hormozgan

Introduction: Radon is a colorless inert gas which decay products are the main component of natural radioactive elements that are naturally produced in under layers of earth crust by decay of radium and uranium. It enters through buildings via gaps and cracks. Radon gas decay products like alpha particle can increase the incidence of lung cancer in human. Since every person sp...

متن کامل

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Measurement of Radon Concentrations and Surface Exhalation Rates using CR-39 detector in Soil Samples of Al-Diwaniyah Governorate, Iraq

Introduction: Natural radioactivity in the soil is considered a major indicator of radiological contamination. Primordial radionuclides are the main source of natural radioactivity. Natural radioactivity transfers radionuclides into the environment and poses radiation hazards to people's health. Therefore, the present study aimed to determine the radon concentration an...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 8  شماره 4

صفحات  25- 32

تاریخ انتشار 2020-08

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023