The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures

نویسندگان

  • Babapour, Ali
  • Qujeq, Dordi
چکیده مقاله:

The Release of Residual Monomeric Methyl Methacrylate in Human Saliva after Using Acrylic Dentures Dr. AH. Alehavaz* - Dr. D. Qujeq** - Dr. A. Babapour*** *- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Babol University of Medical Sciences. **- Associate Professor of Biochemistry and Biophysics Dept. – Babol University of Medical Sciences. ***- Dentist. Background and Aim: Autopolymerized and heat polymerized acrylic resins are widely used in dentistry for various purposes. Despite the polymerization method, the conversion of monomer into polymer is not complete and varying amounts of free or unreacted monomer (residual monomer) remain in the polymerized resin. The aim of this study was to determine the residual monomeric methyl metacrylate content in the saliva of patients using acrylic dentures, at different time intervals. Materials and Methods: Informed consents were obtained from 25 patients with complete dentures, ranging in age from 35 to 65 years. 1 mL samples of whole saliva were collected upon insertion of the dentures and 1day, 1week and 1month after wearing them. Methyl methacrylate (MMA) levels were measured by use of gas chromatography. Data were analyzed by repeated measurement ANOVA and paired sample T-tests. Results: The maximum concentration of monomer released into saliva was detected one day after insertion of the dentures. The Mean (SD) MMA content in saliva was 0.4±0.12 (ng/ml) upon insertion, and 0.7±0.16 (ng/ml), 0.5±0.13 (ng/ml), and 0.38± 0.1 (ng/ml) on the 1st day, 1st week and 1st month post-insertion, respectively. Conclusion: The maximum amount of monomer released by heat-polymerized poly-MMA was observed on the first day after insertion, which, while not a toxic or primary irritant dose, could sensitize patients or elicit an allergic reaction. For minimization of the adverse effects, patients could be advised not to wear their dentures overnight, 24 hours after delivery. Key words: Saliva - Methyl methacrylate - Residual monomer - Denture base

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Degradation of methacrylate monomers in human saliva.

This study assessed the effect of the molecular structure of newly synthesized methacrylate monomers on their chemical stability in human saliva, whereby these monomers can be used as dental composite resins. Six model monomethacrylates and two urethane-modified BisGMA monomers were added to human saliva, and their change in concentration after 24, 48, and 72 hours were measured by high-perform...

متن کامل

Cisplatin delivery from poly(acrylic acid-co-methyl methacrylate) microparticles.

To develop a platform for tumor chemotherapy, poly(acrylic acid-co-methyl methacrylate) microparticles have been synthesized. Carboxylate containing monomers were included to complex therapeutic agents, specifically cisplatin. Microparticles were prepared by free radical emulsion polymerization in aqueous media. Particle diameter, zeta-potential, in vitro cytotoxicity, and in vivo acute toxicit...

متن کامل

Release of methyl methacrylate from heat-cured and autopolymerized resins: cytotoxicity testing related to residual monomer.

Three heat-cured and three autopolymerized acrylic denture bases with different mixing proportions and/or processing methods were investigated for the amount of residual monomer content and methyl methacrylate (MMA) released into saliva after incubation during the first and second 24 hours after processing. A corresponding range of concentrations of MMA was also used to test for cell cytotoxici...

متن کامل

Comparison of poly (methyl methacrylate) and acrylic hydrophobic intraocular lens surface irregularities using atomic force microscopy

Background: Posterior capsule opacification (PCO) is a very frequent complication of phacoemulsification surgery in patients undergoing cataract extraction. This has led to modifications in design and material of intraocular lenses (IOLs). There is increasing evidence suggesting that foldable acrylic hydrophobic IOLs are associated with lower PCO incidence. However, traditional rigid poly methy...

متن کامل

Artificial saliva effect on toxic substances release from acrylic resins.

BACKGROUND/AIM Acrylic-based resins are intensively used in dentistry practice as restorative or denture-base materials. The purpose of this study was to analyze the surface structure of denture base resins and the amount of released potentially toxic substances (PTS) immediately upon polymerization and incubation in different types of artificial saliva. METHODS Storage of acrylic samples in ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ذخیره در منابع من قبلا به منابع من ذحیره شده

{@ msg_add @}


عنوان ژورنال

دوره 18  شماره 2

صفحات  81- 85

تاریخ انتشار 2006-05

با دنبال کردن یک ژورنال هنگامی که شماره جدید این ژورنال منتشر می شود به شما از طریق ایمیل اطلاع داده می شود.

کلمات کلیدی

کلمات کلیدی برای این مقاله ارائه نشده است

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023