Journal: :Journal of agricultural and food chemistry 2003
Weilin L Shelver David J Smith

A biosensor method, using the surface plasmon resonance (SPR) principle, was developed for the determination of ractopamine in cattle and sheep urine. A monoclonal antibody was used to compete with ractopamine in the sample and ractopamine immobilized on the sensor chip. Addition of bovine serum albumin (BSA, 1 mg/mL) as an antibody stabilizer to the incubation buffer was required to achieve a ...

2015
Lee Fung Ang Lip Yee Por Mun Fei Yam

An amperometric enzyme-electrode was introduced where glucose oxidase (GOD) was immobilized on chitosan membrane via crosslinking, and then fastened on a platinum working electrode. The immobilized enzyme showed relatively high retention activity. The activity of the immobilized enzyme was influenced by its loading, being suppressed when more than 0.6 mg enzyme was used in the immobilization. T...

Journal: :Plant physiology 2014
Sathish Rajamani Moacir Torres Vanessa Falcao Jaime Ewalt Gray Daniel A Coury Pio Colepicolo Richard Sayre

We have developed a fluorescence resonance energy transfer (FRET)-based heavy metal biosensor for the quantification of bioavailable free heavy metals in the cytoplasm of the microalga Chlamydomonas reinhardtii. The biosensor is composed of an end-to-end fusion of cyan fluorescent protein (CFP), chicken metallothionein II (MT-II), and yellow fluorescent protein (YFP). In vitro measurements of Y...

2017
Mahbubur Rahman Lee Yook Heng Dedi Futra Tan Ling Ling

An ultrasensitive electrochemical biosensor for the determination of pathogenic Vibrio cholerae (V. cholerae) DNA was developed based on polystyrene-co-acrylic acid (PSA) latex nanospheres-gold nanoparticles composite (PSA-AuNPs) DNA carrier matrix. Differential pulse voltammetry (DPV) using an electroactive anthraquninone oligonucleotide label was used for measuring the biosensor response. Loa...

2016
Babu

I would like to model and simulate 3D label free Nano Amperometric Biosensor for drug delivery and detection of cancerous cells. An Amperometric biosensor is one which has a biological element and a transducer. The analysis to whom the transduction to take place is referred to as analyte. The biological element I use in my work is enzyme, it can be even a living cell, DNA and proteins. Enzyme w...

2016
Svitlana V. Marchenko Oleksandr O. Soldatkin Berna Ozansoy Kasap Burcu Akata Kurc Alexei P. Soldatkin Sergei V. Dzyadevych

In the work, silicalite particles were used for the surface modification of pH-sensitive field-effect transistors (pH-FETs) with the purpose of developing new creatinine-sensitive biosensor. Creatinine deiminase (CD) adsorbed on the surface of silicalite-coated pH-FET served as a bioselective membrane. The biosensor based on CD immobilized in glutaraldehyde vapor (GA) was taken as control. The ...

2016
Guey-Horng Wang Chiu-Yu Cheng Man-Hai Liu Tzu-Yu Chen Min-Chi Hsieh Ying-Chien Chung

Fast hexavalent chromium (Cr(VI)) determination is important for environmental risk and health-related considerations. We used a microbial fuel cell-based biosensor inoculated with a facultatively anaerobic, Cr(VI)-reducing, and exoelectrogenic Ochrobactrum anthropi YC152 to determine the Cr(VI) concentration in water. The results indicated that O. anthropi YC152 exhibited high adaptability to ...

2016
Wanida Tangkawsakul Toemsak Srikhirin Kazunari Shinbo Keizo Kato Futao Kaneko Akira Baba

In this study, we demonstrate a long-range surface plasmon resonance (LR-SPR) biosensor for the detection of whole cell by captured antigens A and B on the surface of red blood cells (RBCs) as a model. The LR-SPR sensor chip consists of high-refractive index glass, a Cytop film layer, and a thin gold (Au) film, which makes the evanescent field intensity and the penetration depth longer than con...

Journal: :Applied and environmental microbiology 2004
Michael Nielsen Lars Hauer Larsen Mike S M Jetten Niels Peter Revsbech

A sensitive NO2- biosensor that is based on bacterial reduction of NO2- to N2O and subsequent detection of the N2O by a built-in electrochemical N2O sensor was developed. Four different denitrifying organisms lacking NO3- reductase activity were assessed for use in the biosensor. The relevant physiological aspects examined included denitrifying characteristics, growth rate, NO2- tolerance, and ...

Journal: :Biosensors & bioelectronics 2013
Jee-Yeon Kim Kyungyong Choi Dong-Il Moon Jae-Hyuk Ahn Tae Jung Park Sang Yup Lee Yang-Kyu Choi

The present work aims to improve the sensitivity of an electrical biosensor by simply changing a surface property of the passivation layer, which covers the background region except for the sensing site for electrical isolation among adjacent interconnection lines. The hydrophobic passivation layer dramatically enhances the sensitivity of the biosensor when compared with a hydrophilic passivati...