In this paper, the ratio of adsorbed dose to the tissues of muscle, blood and bone to water for medical accelerators of Electa 25MV and Siemens 6MV is calculated using an analytical method based on cavity theory and Monte Carlo simulation. To confirm the validation of these methods, the ratio of absorbed dose to air to water was determined experimentally for radiation field of 60Co in Secondary...
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...
the monte carlo method can be used to describe any technique that approximates solutions to quantitative problems through statistical sampling. this method is considered to be the most accurate method for dose calculation in radiotherapy. for complete modeling of a linear accelerator, it is required that the manufactured information covers all data, but some data such as primary electron energy...
Introduction The use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (PDD) curves. These changes and electron beam dose distribution in the form of three-dimensional (3D) can be measured by gel dosimeters. Materials and Methods Dosimetry was performed with and without a square shield (6×6 cm2 field). The energies were 4, 9, and 16 MeV and phantom w...
Introduction: Total body irradiation (TBI) is a form of external beam radiotherapy which is used in conjunction with chemotherapy with the purpose of immunosuppression. Since the target in TBI is the whole body so a uniform dose distribution throughout the entire body during TBI is necessary. As recommended by AAPM dose variation must be within ±10% of prescription dose. A revi...
this study was conducted in the research field of iranian research institute of plant protection in karaj as strip split plots with three replications. the first factor: tillage and no-tillage, and the second factor: herbicide: glyphosate 6 l/ha, 2,4-d + mcpa 2l/ha, glyphosate + 2,4-d + mcpa (6 + 2 l/ha), glyphosate 3 l/ha, 2,4-d + mcpa 1 l/ha, glyphosate + 2,4-d + mcpa (3 + 1 l/ha), and contro...
Although treatment planning systems are generally thought to have poor accuracy for out-of-field dose calculations, little work has been done to quantify this dose calculation inaccuracy for modern treatment techniques, such as intensity-modulated radiation therapy (IMRT), or to understand the sources of this inaccuracy. The aim of this work is to evaluate the accuracy of out-of-field dose calc...