نتایج جستجو برای: low voltage ride through capability

تعداد نتایج: 2548878  

1999
Raj Narayanan Don Platt Sarath Perera

Voltage sags originating in ac supply systems can cause nuisance tripping of variable speed drives (VSDs) resulting in production loss and restarting delays. In ac VSDs having an uncontrolled rectifier front-end, the effects of voltage sags on the dc link causing dc under-voltage or ac overcurrent faults initiate the tripping. This paper suggests modifications in the control algorithm in order ...

Journal: :Electronics 2022

The uninterruptible operation of grid-connected renewables under the occurrence grid voltage sags is addressed in this work. This achieved due to incorporation an enhanced control algorithm a renewable source. low-voltage ride-through was developed accordance profile introduced by IEC 61400-21 regarding sags. To guarantee continuous agent during sags, not only instantaneous reactive power but a...

Journal: :Electrical Engineering 2023

Abstract The increasingly popular inverter distributed generation in microgrids is leading to changes system fault characteristics. behaviors of are closely related the control mode. Here, a photovoltaic power supply constant mode enters low-voltage ride-through state when there microgrid. output current phase analyzed, and local protection method based on difference feeder positive-sequence pr...

In the event of voltage sag at the nearing of a wind park, severe currents may pass through the power electronic devices of the Doubly Fed Induction Generators (DFIGs). Hence, according to the Low Voltage Ride Through (LVRT) requirements, the wind parks are allowed to disconnect from the network after a certain time. Therefore, to avoid such actions, the LVRT requirement of wind parks is consid...

DFIG based wind turbines (WTs) are very sensitive to grid voltage dips. This is because the grid voltage dips imposed at the connection point of the DFIG to the grid induce large voltages in the rotor windings, resulting in high rotor current. According to high penetration of DFIG based WTs, it is important that the WTs remain connected to the grid during the voltage dips and improve the grid s...

2017
Priyanka R. Patil

Although the introduction of distributed generation (DG) in a distribution system improves the power quality of power system, it increases the fault current level reducing voltage at point of common-coupling (PCC). Hence, there is a need of improving fault ride-through (FRT) capability to avoid sudden tripping of DG units from the utility grid during voltage sag in a faulty condition. In this p...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تحصیلات تکمیلی صنعتی کرمان - پژوهشکده برق و کامپیوتر 1390

a phase-locked loop (pll) based frequency synthesizer is an important circuit that is used in many applications, especially in communication systems such as ethernet receivers, disk drive read/write channels, digital mobile receivers, high-speed memory interfaces, system clock recovery and wireless communication system. other than requiring good signal purity such as low phase noise and low spu...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید