نتایج جستجو برای: mcnp calculation

تعداد نتایج: 102713  

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

ژورنال: سنجش و ایمنی پرتو 2020

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...

2011
H Omar K Khattab N Ghazi

The neutron energy spectra have been calculated in the fuel region, inner and outer irradiation sites of the zero power research reactor using the MCNP-4C code and the combination of the WIMS-D/4 transport code for generation of group constants and the three-dimensional CITATION diffusion code for core analysis calculations. The neutron energy spectrum has been divided into three regions and co...

2013
Sedigheh Sina Reza Faghihi Ali Soleimani Meigooni Zahra Siavashpour Mohammad Amin Mosleh-Shirazi

BACKGROUND The old Treatment Planning Systems (TPSs) used for intracavitary brachytherapy with Cs-137 Selectron source utilize traditional dose calculation methods, considering each source as a point source. Using such methods introduces significant errors in dose estimation. As of 1995, TG-43 is used as the main dose calculation formalism in treatment TPSs. OBJECTIVES The purpose of this stu...

2000
Gregg C. Giesler

MCNP is the Monte Carlo N-Particle radiation transport code whose history dates back more than half a century to the early days of computing. From a simple beginning, its uses have grown to include fields such as criticality safety, radiation shielding, oil well logging, and medical imaging and diagnostics and an international user community of over 3000 users. This large user community could o...

ژورنال: سنجش و ایمنی پرتو 2016

In this research, a method for considering the spatial variation of deal layer (DL) thickness at the lateral and top surfaces of HPGe detectors is presented to achieve a more precise simulation model for efficiency calculation especially in marinelli beaker geometries. As a good approximation, the lateral surface of the detector is divided into 12 segments, assuming each segment covers 30 degre...

2002
N J Roberts

The manganese bath method for measuring the neutron emission rate of radionuclide sources requires corrections to be made for emitted neutrons which are not captured by manganese nuclei. The Monte Carlo particle transport code MCNP has been used to calculate the fractions of neutrons that escape from the boundaries of the tank, that are captured by the steel cavity in which the source is housed...

1999
N. A. Hanan A. P. Olson R. B. Pond J. E. Matos

The REBUS-3 burnup code, used in the ANL RERTR Program, is a very general code that uses diffusion theory (DIF3D) to obtain the fluxes required for reactor burnup analyses. Diffusion theory works well for most reactors. However, to include the effects of exact geometry and strong absorbers that are difficult to model using diffusion theory, a Monte Carlo method is required. MCNP, “a general-pur...

2012
Matthew R. Halstead Sangjin Lee James Petrosky Abigail Bickley Paul Sokol

The energy spectrum of the Neutron Radiation Effects Program (NREP) beam line, Target-ModeratorReflector-1 (TMR-1), at Indiana University has not been previously characterized. The facility has a unique proton source with variable pulse length (15-600 s) and energy (13 MeV). Thus, it can produce a unique and tailored neutron beam when incident on a beryllium target. Through a combination of MCN...

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2012
Mohammad Taghi Bahreyni Toossi Mehdi Momennezhad Seyed Mohammad Hashemi

AIM Exact knowledge of dosimetric parameters is an essential pre-requisite of an effective treatment in radiotherapy. In order to fulfill this consideration, different techniques have been used, one of which is Monte Carlo simulation. MATERIALS AND METHODS This study used the MCNP-4C to simulate electron beams from Neptun 10 PC medical linear accelerator. Output factors for 6, 8 and 10 MeV el...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید