نتایج جستجو برای: polymer gel dosimeter

تعداد نتایج: 195878  

Journal: :Physics in medicine and biology 2001
P M Fong D C Keil M D Does J C Gore

Polymer gels whose NMR and optical properties change when irradiated offer unique advantages for measuring radiation dose distributions. To date, all acrylic polymer gel dosimeters must be manufactured, stored and irradiated in hypoxic conditions which severely limits their use and stability. A new formulation of acrylic dosimeter gel has been developed that responds well in normal atmosphere a...

2010
A E Papadakis T G Maris G Zacharakis J Ripoll

We present initial results on the comparison of the dose readout from a three dimensional polymer gel dosimeter using two different optical-CT systems; i) a common wide field and a wide area detector optical-CT system and ii) a new ‘laser-line’ and wide area detector based optical-CT system. The findings presented herein highlight the advantage of the laser based over the wide field optical-CT ...

M. Allahverdi, M.H. Zahmatkesh, Mahbod Sedaghat, R. Jaberi, Sh. Akhlaghpoor,

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

Gh. Ataei M. Khadem-Abolfazli M. Mahdavi, S. R. M. Mahdavi

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within the gel medium with used of conformal distribution gold nanoparticle as contrast agents by high atomic number material.Methods: In this work t...

Journal: :Journal of Physics: Conference Series 2017

2014
A Asena T Kairn S B Crowe S T Smith

This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for atte...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

Background: Numerous unique characteristics of the nanosized gold, including high atomic number, low toxicity, and high biocompatibility make it one of the most appropriate nanostructures to boost radiotherapy efficacy. Many in-vivo and in-vitro investigations have indicated that gold nanoparticles (AuNPs) can significantly increase tumor injuries in low kilovoltage radiotherapy. While deep-lyi...

2016
Hossein Masoumi Manijhe Mokhtari-Dizaji Azim Arbabi Mohsen Bakhshandeh

In this study, using methacrylic and ascorbic acid in gelatin initiated by copper (MAGIC-f) polymer gel after megavoltage energy exposure, the sensitivity of the ultrasound velocity and attenuation coefficient dose-dependent parameters was evaluated. The MAGIC-f polymer gel was irradiated under 1.25 MeV cobalt-60, ranging from 0 to 60 Gy in 2-Gy steps, and received dose uniformity and accuracy ...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید