نتایج جستجو برای: uniform seismic hazard spectra uhs

تعداد نتایج: 316146  

2004
Tzu-Yang Yu

The goals of seismic impact assessment can be achieved by seismic monitoring systems and seismic impact simulator. Seismic monitoring system, for the purpose of hazard analysis, local site effects analysis, vulnerability analysis, and estimation of loss, is one application of SHM in earthquake engineering. A prototype, conceptual seismic impact simulator integrating SHM, FEM, GIS, and Virtual R...

The present study assesses the seismic performance of steel moment resisting frames (SMFs) retrofitted with different bracing systems. Two structural configurations were utilized: ordinary concentrically braces (OCBFs), buckling-restrained braces (BRBFs). A 7-story and 18-story steel perimeter SMFs were designed with insufficient lateral stiffness to satisfy code drift limitations in high seism...

 Today, the resiliency of the human centers, especially urban centers against the natural hazards such as earthquakes, is one of the main challenges in the targeted management of urban. One of the effective strategies in the control, containment and prevention of risks from earthquakes is zoning of urban areas in terms of vulnerability. In this regard, the purpose of this study was to determine...

2006
F. G. Perez C. T. Higgins

The California Seismic Hazards Mapping Act of 1990 directs the California Geological Survey (CGS) to delineate seismic hazard zones of required investigation for earthquake-induced ground failures specifically, liquefaction and seismically triggered landslides. To date, more than 100 official Seismic Hazard Zone maps have been released, covering 200 cities and unincorporated areas in ten counti...

Journal: :Bulletin of the New Zealand Society for Earthquake Engineering 1993

Journal: :Journal of Seismology 2006

Journal: :Geological Survey of Denmark and Greenland (GEUS) Bulletin 2007

2015
Meng-Tse Gabriel Lee Hsuan-Mao Wang Ja-An Annie Ho Nien-Chu Fan Ya-Lin Yang Chien-Chang Lee Shyr-Chyr Chen Michael Bader

BACKGROUND Current research suggests that administration of vasopressin to patients with uncontrolled hemorrhagic shock (UHS) can avoid the detrimental effects associated with aggressive fluid resuscitation. However, vasopressin has a short half-life of 10~35 minutes in in vivo use and precludes its use in the pre-hospital setting. To increase the half-life of vasopressin, we proposed to synthe...

Journal: :Journal of Natural Disaster Science 2012

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید