نتایج جستجو برای: cerium iii selective sensor
تعداد نتایج: 638426 فیلتر نتایج به سال:
Penggunaan cerium dalam aplikasi sensor telah banyak dikembangkan. Dalam penelitian ini, biosensor elektrokimia dikembangkan untuk mendeteksi DNA mitokondria Sus scrofa menggunakan screen printed carbon elektrode -cerium (SPCE-Ce). Permukaan SPCE sebelum dan sesudah dimodifikasi dengan dikarakterisasi Scanning Electron Microscopy (SEM) voltammetri siklik (CV). Desain urutan nukleotida babi seba...
Cu/ZnO/A1203 catalysts modified by compounds of manganese or cerium were prepared by coprecipitation or by impregnation and were tested for the synthesis of alcohol mixtures from synthesis gas at pressures of up to 70 bar. They were also examined by XPS both before and after the reaction. With both the impregnated and the coprecipitated catalysts, manganese increased the selectivity to higher a...
The localized corrosion behavior of a galvanic aluminum copper couple was investigated by in situ fluorescence imaging with a fiber-optic imaging sensor. Three different, but complementary methods were used for visualizing remote corrosion sites, mapping the topography of the metal surface, and measuring local chemical concentrations of H+, OH-, and Al3+. The first method is based on a pH-sensi...
A simple and sensitive spectrofluorimetric method was developed for the determination of biotin in pure form and in pharmaceutical preparations. The proposed method is based on the oxidation of the drug with cerium (IV) ammonium sulfate in acidic medium. The fluorescence of the produced Cerium (III) was measured at 365 nm after excitation at 255 nm. The different experimental parameters affecti...
abstract ion selective electrodes (ises) are electrochemical sensors that respond selectivity to the activity of ionic species. an ion-selective electrode is an electrochemical device that uses a thin selective membrane or film as the recognition element, and is an electrochemical half-cell equivalent to other half-cells of the zeroth (inert metal in a redox electrolyte). in common methods o...
The RM1 model for the lanthanides is parameterized for complexes of the trications of lanthanum, cerium, and praseodymium. The semiempirical quantum chemical model core stands for the [Xe]4fn electronic configuration, with n =0,1,2 for La(III), Ce(III), and Pr(III), respectively. In addition, the valence shell is described by three electrons in a set of 5d, 6s, and 6p orbitals. Results indicate...
Peptide nucleic acid (PNA) is one of the most widely used synthetic DNA analogs. Conjugation of functional molecules to PNA is very effective to further widen its potential applications. For this purpose, here we report the synthesis of several ligand monomers and introduced them to PNA. These ligand-modified PNAs attract cerium ion and are useful for site-selective DNA hydrolysis. It should be...
soil salinity has been a large problem in arid and semi arid regions. preparation of such maps is useful for natural resource managers. old methods of preparing such maps require a lot of time and cost. multi-spectral remotely sensed dates due to the broad vision and repeating of these imageries is suitable for provide saline soil maps. this investigation is conducted to provide saline soil map...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید