نتایج جستجو برای: glass membrane electrode

تعداد نتایج: 516981  

   In this study, effect of asymmetric functionalized graphene oxide (Janus GO) on Young′s modulus and glass transition temperature of Polysulfone (PSf) ultrafiltration membranes was investigated. The membranes were prepared via phase inversion method and GO nanosheets were dispersed in casting solution by sonication. Results showed that the Normalized Young’s modulus (on the basis of neat ...

H. Aghaie M. Giahi M. Zawari

In this research, a PVC membrane electrode for Manganese (II) ions based on N-(2-Picolinamidoethyl)Picolinamide as neutral carrier was prepared. The electrode exhibits a Nemstian responseover Mn(II) concentration range of (1.0 x10-5 t01.0 X 10-1M) with a slope of 29.3±0.5 mV perdecade of concentration with a working pH range of 4.0-9.0. It has a fast response time (

Journal: :Analytical chemistry 2011
Glen D O'Neil Raluca Buiculescu Samuel P Kounaves Nikos A Chaniotakis

There is currently a need for a reliable solid-state reference electrode, especially in applications such as autonomous sensing or long-term environmental monitoring. We present here for the first time a novel solid-state nanofiber junction reference electrode (NFJRE) incorporating a junction consisting of poly(methyl methacrylate) and carbon graphene stacked nanofibers. The NFJRE operates by u...

2007
P. Happel I. D. Dietzel

The scanning ion conductance microscope is a tool to investigate non-conducting surfaces in electrolyte solutions. It is based on the measurement of the change in access resistance arising when an electrolytefilled glass electrode approaches a non-conducting surface. The resistance changes before a mechanical contact between electrode tip and sample surface occurs and thus allows one to image s...

2014
Pingping Gou Nadine D. Kraut Ian M. Feigel Hao Bai Gregory J. Morgan Yanan Chen Yifan Tang Kara Bocan Joshua Stachel Lee Berger Marlin Mickle Ervin Sejdić Alexander Star

The ability to accurately measure real-time pH fluctuations in-vivo could be highly advantageous. Early detection and potential prevention of bacteria colonization of surgical implants can be accomplished by monitoring associated acidosis. However, conventional glass membrane or ion-selective field-effect transistor (ISFET) pH sensing technologies both require a reference electrode which may su...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2009
Toshio Nakamura

The potentiometric response of electrodes is described, including: (1) Nernstian response to activity change due to an altered concentration of the analyte ion, and (2) Nernstian response to activity change caused by different solvents. In order to ensure the reliability of the data obtained in this study, the following three steps were taken: (i) a comparison of electrode potentials between a ...

Journal: :Circulation research 1973
K Hermsmeyer

Multiple-electrode extracellular recording was used to determine the degree to which membrane electrical activity spreads through the rat anterior mesenteric-hepatic portal vein. Glass-pore electrodes filled with physiological salt solution were placed against the isolated intact vein or longitudinal strips of vein at 1-mm intervals to record spontaneous spiking. No pressure electrode effect wa...

Manganese plays a key role in the health of human beings therefore, its determination is very important in medical fields. In this regards, a novel coated graphite electrode was constructed for determination of manganese (II) by using zolpidem as an ionophore, for the first time. The best performance was obtained of the membrane composition of PVC (32%), Potassium tetrakis (4-chlorophenyl) bora...

Forogh Adhami Leila Hajiaghababaei Saeid Takalou

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

Journal: :The Journal of physiology 1969
R C Thomas

1. Sodium was injected into an identified snail neurone by passing current between two intracellular micro-electrodes, the membrane potential being recorded with a third micro-electrode.2. The injection of about 25 p-equiv Na, but not the injection of similar quantities of K or Li, caused a hyperpolarization of up to 20 mV. This response to Na injection was blocked by application of ouabain or ...

نمودار تعداد نتایج جستجو در هر سال