نتایج جستجو برای: ionization radiation

تعداد نتایج: 273398  

Journal: :Physical review letters 2008
Paul J Tanner Jianing Han E S Shuman T F Gallagher

In a dense gas of 300 microK 85Rb atoms of n approximately 50 ionization occurs on a 100 ns time scale, far too fast to be explained by the motion of the atoms or photoionization by 300 K blackbody radiation. Rapid ionization is accompanied by spectral broadening, with the spectrum becoming continuous at n=88 at a density of 5x10(10)cm(-3). The atomic transitions broaden both smoothly and by th...

2000
N. P. S. Sidhu Alkis Rouvas Patrick Cadman

The use of a radioactive check device containing Strontium 90 was investigated to carry out the redundancy checks of Farmer-type ionization chambers. It was not possible to meet the recommended tolerance limits of the redundancy checks without taking into account the angular response of the ionization chambers. The ionization chambers exhibited a maximum variation of 1% in the angular response ...

2001
G. D. Alton

In this report, emphasis is placed on issues related to selection and design of high-temperature, ion sources that have demonstrated the high ionization efficiency, species versatility, and operational reliability required at ISOL based radioactive ion beam facilities. In designing sources for ISOL applications, careful attention must be given to the following: selecting the most appropriate ma...

ژورنال: سنجش و ایمنی پرتو 2020

According to International Atomic Energy Agency (IAEA) recommendations, the calibration of ionization chambers used for radiotherapy dosimetry follows the substitution method which demands the use of a reference ionization chamber. This work introduces the Design and fabrication of cylindrical ionization chamber for dosimetry to be used by standard dosimetry laboratories. The result of the qual...

Journal: :The journal of physical chemistry letters 2012
Debashree Ghosh Amir Golan Lynelle K Takahashi Anna I Krylov Musahid Ahmed

The ionization energy of gas-phase deoxyribose was determined using tunable vacuum ultraviolet synchrotron radiation coupled to an effusive thermal source. Adiabatic and vertical ionization energies of the ground and first four excited states of α-pyranose, the structure that dominates in the gas phase, were calculated using high-level electronic structure methods. An appearance energy of 9.1(±...

2014
Kyoung Won Jang Sang Hun Shin Seon Geun Kim Jae Seok Kim Wook Jae Yoo Young Hoon Ji Bongsoo Lee

In this study, a wavelength shifting fiber that shifts ultra-violet and blue light to green light was employed as a sensor probe of a fiber-optic Cerenkov radiation sensor. In order to characterize Cerenkov radiation generated in the developed wavelength shifting fiber and a plastic optical fiber, spectra and intensities of Cerenkov radiation were measured with a spectrometer. The spectral peak...

Journal: :Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine 2012
Ana P Perini Lucio P Neves Vitor Vivolo Marcos Xavier Helen J Khoury Linda V E Caldas

A pencil-type ionization chamber, developed at Instituto de Pesquisas Energéticas e Nucleares (IPEN), was characterized with the objective to verify the possibility of its application in radiation field mapping procedures. The characterization tests were evaluated, and the results were satisfactory. The results obtained for the X radiation field mapping with the homemade chamber were compared w...

2005
Lesley A. Buckley

Radiation dosimetry is used to quantify the dose delivered during radiation therapy by using ionization chambers with several correction factors. Knowledge of these factors is needed at well below the 1% level in order to maintain the overall uncertainty on the reference dosimetry near 1-2%. The small magnitude of the corrections renders measurements very difficult. Monte Carlo calculations are...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید