نتایج جستجو برای: planning target volume
تعداد نتایج: 886017 فیلتر نتایج به سال:
An improved correlation based Particle Tracking Velocimetry (PTV) algorithm was proposed in the present paper. The path tracking of the tracer particles was achieved through a correlation operation of the small interrogation window around the studied tracer particles at two-time steps. The central positions of the tracer particles were determined by the correlation operation of the tracer parti...
An investigation in Panama found that Punta Toro virus species complex (PTVs) may contribute to febrile illnesses with symptoms mirroring those of dengue fever. However, further studies are needed to determine if PTV infection causes only a mild disease or if it can have more serious manifestations in some patients.
The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1 (30o X 0.6 mm) and G2 (45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insert...
INTRODUCTION The accuracy of radiation delivery is increasingly important as radiotherapy technology continues to develop. The goal of this study was to evaluate intrafractional motion during intracranial radiosurgery and the relationship between motion change and treatment time. METHODS AND MATERIALS A total of 50 treatment records with 5988 images, all acquired during treatments with the Cy...
A parameter optimization algorithm for intensity‐modulated radiotherapy prostate treatment planning*
An iterative algorithm has been developed to analytically determine patient specific input parameters for intensity-modulated radiotherapy prostate treatment planning. The algorithm starts with a generic set of inverse planning parameters that include dose and volume constraints for the target and surrounding critical structures. The overlap region between the target volume and the rectum is us...
PURPOSE We evaluated whether the field-in-field (FIF) technique improves the homogeneity of the target in high tangent radiation therapy (HTRT). MATERIALS AND METHODS This study included 30 patients. In total, 3 HTRT plans were created: 1 with conventional opposed fields (Conv-p), 1 with the FIF technique (FIF-p), and 1 with FIF technique using lung-blocked subfields (FIF-LB-p). RESULTS The...
BACKGROUND Radiation delivery for malignant brain tumors is gradually becoming more precise. Particularly the possibilities of sparing adjacent normal structures such as the hippocampus are increasing. To determine its radiation exposure more exactly, the equivalent uniform dose (EUD) of the hippocampus was compared with further treatment parameters. This way sparing options could be found. M...
Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...
This study investigates the dosimetric benefits of designing patient-specific margins for prostate cancer patients based on 4D localization and tracking. Ten prostate patients, each implanted with three radiofrequency transponders, were localized and tracked for 40 fractions. "Conventional margin" (CM) planning target volumes (PTV) and PTVs resulting from uniform margins of 5 mm (5M) and 7 mm (...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید