نتایج جستجو برای: planning target volume

تعداد نتایج: 886017  

2014
Buhong Zheng Zhiyu Huang Jinluan Li Qinghui Zhang

PURPOSE To investigate the impact of clinical target volume (CTV) shape and size on CTV to planning target volume (PTV) margin expansion. METHODS AND MATERIALS Using numerical integration methods, margins accounting for random errors and systematic errors were calculated for CTVs of different shapes and sizes. We use k(r-95) and k(s-95) to represent the coefficients, for random errors and sys...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2004
Sergio Díez Javier García Francisco Sendra

BACKGROUND AND PURPOSE A system for the detection, measurement and analysis of the periodic physiological organ motion during radiotherapy treatment is proposed and clinically tested in this paper. MATERIAL AND METHODS The procedure is based on the acquisition of fluoroscopic sequences, followed by an automatic detection of the movement using cross-correlations with matched filters. RESULTS...

Journal: :Physics in medicine and biology 2006
Mustafa Y Sir Stephen M Pollock Marina A Epelman Kwok L Lam Randall K Ten Haken

In radiotherapy a common method used to compensate for patient setup error and organ motion is to enlarge the clinical target volume (CTV) by a 'margin' to produce a 'planning target volume' (PTV). Using weighted power loss functions as a measure of performance for a treatment plan, a simple method can be developed to calculate the ideal spatial dose distribution (one that minimizes expected lo...

2016
Hosang Jin Vance P. Keeling Imad Ali Salahuddin Ahmad

Dosimetric consequences of positional shifts were studied using frameless Brainlab ExacTrac X-ray system for hypofractionated (3 or 5 fractions) intracranial stereo-tactic radiotherapy (SRT). SRT treatments of 17 patients with metastatic intracranial tumors using the stereotactic system were retrospectively investigated. The treatments were simulated in a treatment planning system by modifying ...

2017
Lucy Wills Rhydian Maggs Geraint Lewis Gareth Jones Lisette Nixon John Staffurth Tom Crosby

BACKGROUND SCOPE 1 was the first UK based multi-centre trial involving radiotherapy of the oesophagus. A comprehensive radiotherapy trials quality assurance programme was launched with two main aims: 1. To assist centres, where needed, to adapt their radiotherapy techniques in order to achieve protocol compliance and thereby enable their participation in the trial. 2. To support the trial's cli...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2015
Qinghui Zhang Weijun Xiong Maria F Chan Yulin Song Chandra Burman

Rotational setup errors are usually neglected in most clinical centers. An analytical formula is developed to determine the extra margin between clinical target volume (CTV) and planning target volume (PTV) to account for setup errors. The proposed formula corrects for both translational and rotational setup errors and then incorporated into margin determination for PTV.

2016
Joel Poder May Whitaker

PURPOSE Inverse planning simulated annealing (IPSA) optimized brachytherapy treatment plans are characterized with large isolated dwell times at the first or last dwell position of each catheter. The potential of catheter shifts relative to the target and organs at risk in these plans may lead to a more significant change in delivered dose to the volumes of interest relative to plans with more ...

Journal: :iranian journal of medical physics 0
mostafa robatjazi ph.d student of medical physics, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran seyed rabie mahdavi assistant professor, medical physics dept., faculty of medicine, tehran university of medical sciences, tehran, iran bahram bolouri assistant professor, radiation oncology dept., faculty of medicine, tehran university of medical sciences, tehran, iran alireza nikoofar assistant professor, radiation oncology dept., faculty of medicine, tehran university of medical sciences, tehran, iran

introduction: recently, magnetic resonance spectroscopic imaging (mrsi), as a functional imaging method, has been used for clinical target volume definition. in this study, we used this method to define the target volume in prostate radiotherapy. material and method: in this study, we used images of 20 prostate cancer cases. mrsi and mri images were fused with ct images. then, treatment plannin...

2014
Arif N Ali Tomi Ogunleye Claire W Hardy Hui-Kuo Shu Walter J Curran Ian R Crocker

BACKGROUND To dosimetrically evaluate the effect of reduced margin radiotherapy on hippocampal dose for glioblastoma multiforme (GBM) patients. METHODS GBM patients enrolled on the Radiation Therapy Oncology Group (RTOG) 0825 trial at our institution were identified. Standard RTOG 0825 expansions were 2 cm + 3-5 mm from the gross tumor volume (GTV) to the clinical tumor volume (CTV) and from ...

Journal: :journal of biomedical physics and engineering 0
t r verma king george medical university,up;lucknow n k painuly king george medical university, up, lucknow, indiaسازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور s p mishra سازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور m shajahan n singh king george medical university, up, lucknow, india m l b bhatt dr.ram manohar lohia institute of medical sciences, lucknow, indiaسازمان اصلی تایید شده: 0 دانشگاه های خارج از کشور

background: inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery. objective: in the present study, the performance of five algorithms via monte carlo, pencil beam, convolution, fast superposition and superposition were evaluated in lung cancer intensity modulated radiotherapy planni...