نتایج جستجو برای: surrogate analyte

تعداد نتایج: 31530  

Journal: :Lab on a chip 2013
Min Huang Betty C Galarreta Arif E Cetin Hatice Altug

Effective analyte delivery is essential to achieve rapid and sensitive biodetection systems. In this article, we present an actively controlled fluidic system integrated with a suspended plasmonic nanohole sensor to achieve superior analyte delivery efficiency and ultrafast sensor response, as compared to conventional fluidic systems. 70 nm sized virus like analyte solution is used to experimen...

Journal: :Clinical chemistry 1986
L M Boscato M C Stuart

Using a modified "two-site" immunoradiometric assay, termed an "interference assay," we have demonstrated the occurrence of non-analyte antibody-binding substances in approximately 40% of serum samples. These substances multivalently bind antibodies from any of several species at a site other than the antigen-binding site. Using a two-site immunoradiometric assay for human choriogonadotropin, w...

2016
Scott M. Berry Hannah M. Pezzi Alex J. LaVanway David J. Guckenberger Meghan A. Anderson David J. Beebe

Analyte isolation is an important process that spans a range of biomedical disciplines, including diagnostics, research, and forensics. While downstream analytical techniques have advanced in terms of both capability and throughput, analyte isolation technology has lagged behind, increasingly becoming the bottleneck in these processes. Thus, there exists a need for simple, fast, and easy to int...

1999
Koenraad Van Leemput Frederik Maes Fernando Bello Dirk Vandermeulen Alan C. F. Colchester Paul Suetens

Quantitative analysis of MR images is becoming increasingly important as a surrogate marker in clinical trials in multiple sclerosis (MS). This paper describes a fully automated model-based method for segmentation of MS lesions from multi-channel MR images. The method simultaneously corrects for MR eld inhomogeneities, estimates tissue class distribution parameters and classiies the image voxel...

2015

Consider a set of 6 points in R × {0, 1}: {(−1, 1), (−1, 1), (−2, 1), (−3, 0), (−3, 0), (−3, 0)}, and suppose we are interested in Prec@1. Note that the optimum model that maximizes prec@1 on these points has a positive sign. We will now show that the model w∗ ∈ R that maximizes the above structural SVM surrogate on these points has a negative sign. On the contrary, let us assume that w∗ has a ...

2017
Adam J H Newton Mark J Wall Magnus J E Richardson

Microelectrode amperometric biosensors are widely used to measure concentrations of analytes in solution and tissue including acetylcholine, adenosine, glucose, and glutamate. A great deal of experimental and modeling effort has been directed at quantifying the response of the biosensors themselves; however, the influence that the macroscopic tissue environment has on biosensor response has not...

2015
Anja Henseleit Carolin Pohl Hans-Michael Kaltenbach Karina Hettwer Kirsten Simon Steffen Uhlig Natalie Haustein Thomas Bley Elke Boschke

We used the interaction between human serum albumin (HSA) and a high-affinity antibody to evaluate binding affinity measurements by the bench-top liSPR system (capitalis technology GmbH). HSA was immobilized directly onto a carboxylated sensor layer, and the mechanism of interaction between the antibody and HSA was investigated. The bivalence and heterogeneity of the antibody caused a complex b...

Journal: :Journal of analytical toxicology 2001
T C Whiting R H Liu W T Chang M R Bodapati

In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contr...

Journal: :Talanta 2007
Ibrahim A Darwish Ashraf M Mahmoud Abdel-Rahman A Al-Majed

Generic simple and sensitive universal enzyme immunoassay approach for the determination of small analytes has been developed to avert the problems associated with small molecule immobilization onto solid phases. The developed assay employed a heterogeneous non-competitive binding format. The assay used anti-analyte antibody coupled to polyacrylamide beads as a solid-phase and beta-d-galactosid...

Journal: :I. J. Bifurcation and Chaos 2004
Marco Thiel M. Carmen Romano Udo Schwarz Jürgen Kurths Jens Timmer

Fourier surrogate data are artificially generated time series, that — based on a resampling scheme — share the linear properties with an observed time series. In this paper we study a statistical surrogate hypothesis test to detect deviations from a linear Gaussian process with respect to asymmetry in time (Q-statistic). We apply this test to a Fourier representable function and obtain a repres...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید