نتایج جستجو برای: total harmonic distortion thd
تعداد نتایج: 882103 فیلتر نتایج به سال:
This paper studies a Fuzzy Logic Control Based (FLCB) Shunt Active Filter (SAF) capable of reducing the total harmonics distortion (THD) in Power System (PS). SAF is one of the key controllers in Flexible Alternating Current Transmission System (FACTS) to control the transmission line voltage and can be used in PS to enhance the power transmission capacity and extend the transient stability. In...
Direct torque control (DTC) is a method applied in induction motor (IM) drives to the speed and of IM accurately independently without feedback signal. However, fast fourier transform (FFT) analysis, total harmonic distortion (THD) high DTC with conventional inverter (CI). Therefore, purpose this study minimize THD affecting drive’s performance. A drive multilevel (MLI) proposed reduce preserve...
One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...
In this paper a voltage mode four quadrant analog multiplier (FQAM) using voltage differencing buffered amplifier (VDBA) based on quarter square algebraic identity is presented. In the proposed FQAM the passive resistor can be implemented using MOSFETs operating in saturationregion thereby making it suitable for integration. The effect of non idealities of VDBA has also been analyzed in this pa...
Multilevel inverter as compared to single level inverters have advantages like minimum harmonic distortion, reduced Electro Magnetic Interference (EMI/RFI) generation and can operate on several voltage levels. In this paper a new topology of cascaded multilevel inverter using reduced number of switches, resulting in higher output voltage levels is proposed. There are five series connected H-bri...
In this brief, a sensorless voltage estimation approach for total harmonic distortion (THD) calculation is proposed to reduce number of sensors in the microgrids. The intelligent method provides cost-effective and reliable THD desired bus multi-bus microgrid based on artificial neural networks (ANNs). method, output current distributed generation units along with are used train ANN offline. tra...
Personal computers draw non-sinusoidal current with odd harmonics more significantly. Power Quality of distribution networks is severely affected due to the flow of these generated harmonics during the operation of electronic loads. In this paper, mathematical modeling of odd harmonics in current like 3, 5, 7 and 9 influencing the power quality has been presented. Live signals have been capture...
Received Sep 19, 2017 Revised Dec 30, 2017 Accepted Jan 17, 2018 Penetration of multilevel inverters (MLI) in to high power and medium voltage application has been increasing because of its advantages. A conventional two level inverter has high harmonic distortion which gives poor power quality. Lot of topologies has been developed to overcome the drawbacks of two level inverter. These topologi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید