2005
Sethuraman Ganesan

More and more sub-stations are retrofitted with numerical relays, meters and monitoring devices. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as Current Transformer (CT) and lead remaining undisturbed. Utilities have standardized on their older current transformers and want to maintain the same current transformer specifications throughout ...

2012
D P BALACHANDRAN R SREERAMA KUMAR B JAYANAND

During the transient period at the start of transformer energization, it experiences a flux linkage that is up to twice its nominal steady state value and saturates the core. This causes a large inrush current to flow which affects the power system stability and power quality especially when the source is weak. Sequential phase energization technique and addition of neutral resistor are the maj...

2001
Seong-Jeub Jeon Gyu-Hyeong Cho

A new primary-side-assisted zero-voltage and zerocurrent switching full bridge dc–dc converter with transformer isolation is proposed. The proposed dc–dc converter uses only one auxiliary transformer and two diodes to obtain ZCS for the leading leg. It has a simple and robust structure, and load current control capability even in short circuit conditions. Possibility of magnetic saturation due ...

2009
JALAL ABDALLAH Jalal Abdallah

This paper deals with diagnostic methods of the internal faults in power transformers. The diagnostic process uses some of the current diagnosis methods (e.g. oil test, dissolved gases analysis (DGA), partial discharge (PD), etc.) to determine the condition of the transformer. In this process, the most frequent diagnostic methods were listed and applied practically to be compared. A conventiona...

2016
Mohammad Bakhshipour Farhad Namdari Mohammad Sedaghat

Among the most noticeable root causes of improper performance in power transformers, internal short circuit faults can be noted and if not quickly be identified and addressed in the accepted time interval, irrecoverable damages such as interruption or even collapse of the network connected to the power transformer would happen. In this contribution, three-phase transformer behaviors under magne...

2013
M. Rasoulpoor

(Received: October 30, 2011; Accepted: December 8, 2011) Abstract: This paper presents a novel technique for transformer differential protection to prevent incorrect operation due to inrush current. The proposed method in this paper is based on time-frequency transform known as the Wavelet transform. The discrete Wavelet transform is used for analysis the differential current signals in time an...

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

This investigation deals with a mathematical model for a distribution transformer including saturation effect. To this end, the equations related to a three phase transformer are specified and the effect of an inter-turn fault is included. Naturally by applying an inter-turn fault the inductance and resistance matrix will change. Thus, unknown quantities of inductances and resistances for compl...

This paper consist of two sections: control and stabilizing approach for chaotic behaviour of converter is introduced in first section of this paper for the removal of harmonic caused by the chaotic behaviour in current converter. For this work, a Time- Delayed Feedback Controller (TDFC) control method for stability chaotic behaviour of buck converter for switching courses in current control mo...