نتایج جستجو برای: lateral load
تعداد نتایج: 270245 فیلتر نتایج به سال:
In general Pile foundations are often subject to more than one load in nature. Two loadings, when simultaneous, cause serious problems the bearing capacity. Therefore, major objective of this study is assessment performance piles under inclined cyclic loads simultaneous with static lateral sandy soil a relative density 70%. A laboratory investigates were conducted determine effect several facto...
Earthquakes are a high-risk natural phenomenon in Indonesia, which is between three tectonic plates: the Eurasian, Pacific, and Indo–Australian plates. This study examines response of bored piles with asymmetrical pile cap Auditorium Building Brawijaya University to seismic loads, still rare conduct this research. assessed based on 3D finite element-numerical approach, where lateral resistance ...
well-known seismic design codes have offered an alternative equivalent static procedure for practical purposes instead of verifying design trials with complicated step-y-step dynamic analyses. such a pattern of base-shear distribution over the building height will enforce its special stiffness and strength distribution which is not necessarily best suited for seismic design. the present study, ...
A review of previous studies shows that there are two general views on how to determine demand in structures through incremental nonlinear static analysis. In the first view, multi-modal methods are used to determine demand in structures. In this view, the applied load pattern is applied to the structure according to the shape of each vibration mode, assuming that the structure deformation foll...
Marcus Brown Department of Mechanical and Materials Engineering, Queen’s University, Kingston, Canada Background Bracing is a treatment option for medial knee osteoarthritis [1] that unloads the medial knee through the application of an external moment (brace moment) [2]. In theory, the brace moment is designed to reduce the total external adduction moment, as disease severity and external addu...
BACKGROUND Lateral compartmental osteoarthritis (LCOA), a major complication after medial mobile-bearing unicompartmental knee arthroplasty (UKA), is highly associated with the increased stress of the lateral compartment. This study aimed to analyze the effects on the stress and load distribution of the lateral compartment induced by lower limb alignment and coronal inclination of the tibial co...
Bioresorbable plates have recently been used with anterior cervical discectomy and fusion (ACDF). Compared with metallic plates, bioresorbable plates provide segmental stabilization with minimal imaging artifact, eventual resorption, and increased load sharing. The objectives of the present study were to determine whether a bioresorbable plate can withstand simulated physiologic static and cycl...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید