نتایج جستجو برای: nonlinear axial strain

تعداد نتایج: 478556  

This paper deals with an analytical approach to predict the nonlinear buckling behavior of functionally graded graphene-reinforced composite laminated cylindrical shells under axial compressive load surrounded by Pasternak’s elastic foundation in a thermal environment. Piece-wise functionally graded graphene-reinforced, composite layers are sorted with different types of graphene distribution. ...

Journal: :international journal of advanced design and manufacturing technology 0
morteza raminnia corresponding author

in this study, thermo-mechanical nonlinear vibration of a polyethylene (pe) cylindrical shell embedded in an elastic foundation was investigated. the shell is reinforced by armchair carbon nanotubes (cnts) where characteristics of the equivalent composite being determined using mori-tanaka model. the elastic medium is simulated using the spring constant of the winkler-type,  . employing nonline...

1999
Guoxiang Gu Andrew Sparks

Local output feedback stabilization with smooth nonlinear controllers is studied for parameterized nonlinear systems of which the linearized system possesses multiple pairs of imaginary eigen-values, and the bifurcated solution is unstable at the critical value of the parameter. Necessary and suucient conditions are sought for stabilization of such nonlinear bifurcated systems based on the proj...

Journal: :Bio-medical materials and engineering 2015
Yaonan Zhang Tingting Sun Yueyang Teng Hong Li Yan Kang

Myocardial elastography (ME) is a strain imaging technique used to diagnose myocardial diseases. Axial and lateral displacement calculations are pre-conditions of strain image acquisition in ME. W.N. Lee et al. proposed a normalized cross-correlation (NCC) and recorrelation method to obtain both axial and lateral displacements in ME. However, this method is not noise-resistant and of high compu...

Journal: :Journal of The Mechanics and Physics of Solids 2022

In this work, we developed a bond-based cohesive peridynamics model (CPDM) and apply it to simulate inelastic fracture by using the meso-scale Xu-Needleman potential . By doing so, have successfully continuum mechanics with intrinsic stress/strain measures as well consistent built-in macro-scale constitutive relations. The main novelties of work are: (1) We shown that stress proposed nonlocal i...

In the present manuscript, the second strain gradient (SSG) is utilized to investigate the primary resonance of a nonlinear Euler-Bernoulli nanobeam is analyzed in this paper...

Journal: :Buildings 2023

The section deformation distribution of reinforced concrete components is nonlinear due to the size effect. Existing analysis models such as plastic hinge and truss element are based on plane cross-section assumption. cannot be accurately simulated. Therefore, in this paper, non-planar strain functions sections established. law influence geometrical characteristics load distributions beam ends ...

Journal: :Nordic concrete research 2022

Abstract This study investigates nonlinear modeling and verification of a reinforced concrete element using the fiber section method. At first, theory related to approach hysteresis models used for cyclic analysis is given. Then, column tested previously in literature modeled simulation results are compared with test results. An acceptable approximation made utilizing only few input parameters:...

In sheet metal forming processes with complex strain paths, a part is subjected to large plastic deformation. This severe plastic deformation leads to high plastic strain localization zones and subsequent accumulation of those strains. Then internal and superficial micro-defects and in other words ductile damage is created. This damage causes quality problems such as fracture. Therefore, design...

Journal: :Journal of orthopaedic research : official publication of the Orthopaedic Research Society 1997
M Wong P Wuethrich M D Buschmann P Eggli E Hunziker

In this study, we investigated the depth-dependent metabolic and structural responses of adult articular cartilage to large-strain, static, unconfined compression. Changes in cell biosynthetic activity and several morphometry-based structural parameters (cell density, cell volume fraction, cell surface-area density, mean cell surface area, and mean cell volume) were measured at eight sites repr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید