نتایج جستجو برای: perchlorate selective electrode
تعداد نتایج: 263113 فیلتر نتایج به سال:
Coated wire lithium ion selective electrode was fabricated using lithium ionophore-VI, 2-nitrophenyl octyl ether (NPOE) and potassium tetrakis(p-chlorophenyl)borate (KTpClPB) on platinum wire. Lithium ion selective electrode was giving Nernstian response from 10 -1 M to 10 -4 M with a detection limit of 3x10 -5 M. The calibration slope of this lithium ion selective electrode was found to be 58....
Conventional ion-selective electrodes with a liquid junction have the disadvantage of potential drift. All-solid-state ion-selective electrodes with solid contact in between the metal electrode and the ion-selective membrane offer high capacitance or conductance to enhance potential stability. Solution-casted chitosan/Prussian blue nanocomposite (ChPBN) was employed as the solid contact layer f...
in this research, a pvc membrane electrode for manganese (ii) ions based on n-(2-picolinamidoethyl)picolinamide as neutral carrier was prepared. the electrode exhibits a nemstian responseover mn(ii) concentration range of (1.0 x10-5 t01.0 x 10-1m) with a slope of 29.3±0.5 mv perdecade of concentration with a working ph range of 4.0-9.0. it has a fast response time (
This paper presents the impedance study of low acyl gellan gum/poly(vinyl pyrrolidone) blend as a host matrix for ion conduction. Low salt content of lithium perchlorate was added into the blend polymer host and the membranes were prepared by the means of solution casting method. The temperature-conductivity of the investigated samples follows the Vogel-Tamann-Fulcher rule. The occurrence of el...
چکیده ندارد.
As part of a study to elucidate the environmental parameters that control microbial perchlorate respiration, we investigated the reduction of perchlorate by the dissimilatory perchlorate reducer Dechlorosoma suillum under a diverse set of environmental conditions. Our results demonstrated that perchlorate reduction by D. suillum only occurred under anaerobic conditions in the presence of perchl...
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
چکیده ندارد.
چکیده ندارد.
in this research, the interaction of hexadecyl trimahyl ammonium bromide (htab) with enzyme ureasehas been investigated comprehensively at different experimental conditions such as ionic strength, proteinconcentration using ion selective membrane electrode of surfactants. the obtained binding isotherms frompotentiometnc studies have been analyzed by different theories such as wyman binding pote...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید