نتایج جستجو برای: potentiometry ion selective membrane electrode

تعداد نتایج: 802881  

2009
Asif Ali Khan Umme Habiba Anish Khan

Poly-o-anisidine Sn(IV) arsenophosphate is a newly synthesized nanocomposite material and has been characterized on the basis of its chemical composition, ion exchange capacity, TGA-DTA, FTIR, X-RAY, SEM, and TEM studies. On the basis of distribution studies, the exchanger was found to be highly selective for lead that is an environmental pollutant. For the detection of lead in water a heteroge...

Journal: :Methods in enzymology 2013
Matthias Kellermeier Helmut Cölfen Denis Gebauer

Despite the importance of crystallization for various areas of research, our understanding of the early stages of the mineral precipitation from solution and of the actual mechanism of nucleation is still rather limited. Indeed, detailed insights into the processes underlying nucleation may enable a systematic development of novel strategies for controlling mineralization, which is highly relev...

ژورنال: مواد پرانرژی 2017

Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...

2012
Emanuel Šucman Jiří BEdnář

Šucman E., Bednář J. (2012): Determination of fluoride in plant material using microwave induced oxygen combustion. Czech J. Food Sci., 30: 438–441. Fluorine is essential in human and/or animal nutrition, thus it is important to know its concentration in a diet. One of the important sources of fluorine for humans is tea, containing relatively high amounts of this trace element. A method for flu...

2012
Tahereh Poursaberi

Combination of the exceptional properties of graphene oxide with the selectivity of lead porphyrin leads to fabricate a novel cysteine-selective sensor. The electrode made of 30% PVC, 53% NPOE, 2% NaTPB and 15% GO-PP was found to show the most favorable behavior. The sensor shows a Nernstian response (58.8 mV decade) in the concentration window of 5.0×10-5.0×10 M with detection limit of 8.0×10 ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه گیلان - دانشکده علوم پایه 1386

چکیده ندارد.

Hassan Khodakarami Hedayat O. Ghourchian

A PVC-based membrane containing cerium phosphate was developed. Unlike the cerium phosphate itself that acts as a cation exchanger, the membrane exhibited anion-exchange properties. Therefore, the utility of this compound as a sensory element for detection of molybdate ions was pursued. The response of molybdate selective electrode based on this membrane was perfectly linear in the concentr...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2008
Eman H El-Naby

The construction and electrochemical response characteristics of poly(vinyl chloride) matrix ion-selective electrodes (ISEs) for dextromethorphan (DXM) hydrobromide are described. The membranes incorporate ion-association complexes of DXM with reineckate salt {[Cr(NH3)2(SCN)4]NH4} or phosphomolybdic acid [H3(PMo12O40)], as electroactive materials and dioctylphthalate or dibutylsebacate as a pla...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Mohammad Reza Ganjali Morteza Rezapour Mohammad Reza Pourjavid Masoud Salavati-Niasari

A cobalt(II) derivative was used as a suitable ionophore for the preparation of a polymeric membrane nitrite-selective electrode. The electrode reveals a Nemstian behavior over a very wide NO2- ion concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) and a very low detection limit (5.0 x 10(-7) M). The potentiometric response is independent of the pH of solution in the pH range 4.0-9.5. The electr...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید