نتایج جستجو برای: wavelet transformer

تعداد نتایج: 49572  

2013
Yan Li Yanchao gao Longnv Li Di Zhang Fangxu Han

DC bias current flowing into the neutral point of power transformer will seriously affect the normal operation of AC power system. In this paper, exciting current, harmonic component of the excitation current, magnetic flux density and noise of transformer were analyzed when the transformer is in the no-load operation state based on field-circuit coupled method. Through the calculation and anal...

The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...

2014
Saurabh Shrivastava Ashfaque Khan Amita Mahor

Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...

Journal: :The Review of scientific instruments 2007
Mingsen Guo K H Lam S Wang K W Kwok Helen L W Chan X Z Zhao

In this study, a modified disk-shaped multiple-output piezoelectric transformer operated at the fundamental radial vibration mode has been presented. A derived equivalent circuit for the multioutput piezoelectric transformer was used to analyze the performance. Two piezoelectric transformers, a symmetrically electroded piezoelectric transformer with dual outputs and an asymmetrically electroded...

2013

For flyback coverters, the transformer is the most important factor that determines the performance such as the efficiency, output regulation and EMI. Contrary to the normal transformer, the flyback transformer is inherently an inductor that provides energy storage, coupling and isolation for the flyback converter. In the general transformer, the current flows in both the primary and secondary ...

2013
Xin-Huai Wang Li Zhang Yin Xu Yan-Fu Bai Cheng Liu Xiaowei Shi

In this paper, a compact tri-band impedance transformer by utilizing stubbed coupling line for matching a load at three arbitrary frequencies is proposed. The transformer is composed of two parts, and each part is constructed from parallel-coupled transmission lines. Two structures with different configurations of the proposed transformer have been given and analyzed. Then, the close-form equat...

2001
T. G. Engel

The analysis, design, and operation of high-voltage, transformer-coupled LC vector inversion generators are presented and discussed. The transformer-coupled LC inversion generator is easy to construct and, compared with Marx-type generators and conventional LC vector inversion generators, requires only one inversion switch, independent of the number of voltage multiplication stages. The transfo...

2009
HUI WANG CHENGJUN HUANG LI ZHANG YONG QIAN JUNHUA LIU LINPENG YAO CANXIN GUO XIUCHEN JIANG

Defects inside insulation of HV XLPE cable accessories can lead to partial discharge (PD) activity. When PD activity happens, leakage current may flow through the grounded line. To acquire the PD current signal, one practicable and effective method is placing a high frequency current transformer (HFCT) winding the grounded line. In order to measure the insulation degradation, a partial discharg...

2008
Xiao-Yuan Chen Jian-Xun Jin

⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer...

2012

This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید