نتایج جستجو برای: selective membrane electrode

تعداد نتایج: 631334  

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Mohammad Reza Ganjali Morteza Rezapour Mohammad Reza Pourjavid Masoud Salavati-Niasari

A cobalt(II) derivative was used as a suitable ionophore for the preparation of a polymeric membrane nitrite-selective electrode. The electrode reveals a Nemstian behavior over a very wide NO2- ion concentration range (1.0 x 10(-6)-1.0 x 10(-1) M) and a very low detection limit (5.0 x 10(-7) M). The potentiometric response is independent of the pH of solution in the pH range 4.0-9.5. The electr...

Journal: :iranian journal of chemistry and chemical engineering (ijcce) 2001
mojtaba shamsipur nahid tavakkoli elham eslami hashem sharghi

two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (l1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (l2) were used as suitable ionophores for the preparation of potassium-selective pvc-membrane electrodes. the resulting electrodes based on l1 and l2 exhibit linear responses to the activity of k+ ions within the concentration ranges of 3.1´10-5 -2.7´10-2 m and 2...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشگاه پیام نور استان یزد - دانشگاه پیام نور مرکز اردکان - دانشکده علوم 1386

چکیده ندارد.

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Mohammad Reza Ganjali Tahereh Poursaberi Morteza Hosseini Masoud Salavati-Niasary Mohammad Yousefi Mojtaba Shamsipur

A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detec...

2004
SAAD S. M. HASSAN

A new liquid membrane electrode for caffeine prepared from a solution of caffeine-picrylsulfonate ion-pair complex in n-octanol is developed. It exhibits Nernstian response in the range of w-·2 to 10M caffeine with a cationic slope of 59 mY/concentration decade. The electrode has a wide working pH range (5.59.5), fast response time (20 seconds1.5 minutes), stable response for at least 30 days a...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2006
M Mazloum Ardakani M Jamshidpour H Naeimi L Moradi

A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a goo...

Journal: :Analytical Letters 2008
Weihong Song Chunhui Wu Hongzong Yin Xiaoyan Liu Panpan Sa Jinyang Hu

A novel approach to prepare homogeneous PbS nanoparticles by phase-transfer method was developed. The preparatory conditions were studied in detail, and the nanoparticles were characterized by transmission electron microscopy (TEM) and UV-vis spectroscopy. Then a novel lead ion-selective electrode of polyvinyl chloride (PVC) membrane based on these lead sulfide nanoparticles was prepared, and t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید