نتایج جستجو برای: luminol

تعداد نتایج: 889  

1999
Jeffrey S. Gaffney Nancy A. Marley Paul J. Drayton

Fast capillary gas chromatography has been coupled to a luminol-based chemiluminescence detection system for the rapid monitoring of nitrogen dioxide and peroxyacyl nitrates. A first-generation instrument was described recently (Gaffney et al., 1998). This system is capable of monitoring nitrogen dioxide and peroxyacyl nitrates (PANs; to and including the C4 species) with 1-min time resolution....

2015
Nawal A Alarfaj Maha F El-Tohamy

BACKGROUND The opioid antagonist agent naloxone hydrochloride (NLX) is a drug that has high affinity for opiate receptors but do not activate these receptors. Owing to the role of this drug to block the effects of exogenous administered opioids and endogenous released endorphians we can deduce the importance of developing sensitive analytical methods for detection of such drug. In the present s...

Journal: :Chemical communications 2012
Wen Shen Yuqi Yu Jiangnan Shu Hua Cui

A bottom-up approach for preparing multifunctional graphene-based materials noncovalently functionalized with CL reagents with aromatic rings such as N-(aminobutyl)-N-(ethylisoluminol) (ABEI), luminol and isoluminol is reported. The as-prepared nanocomposites exhibit good CL activity, which may find future applications in analytical, electrochemical and biomedical fields.

Journal: :Journal of the Magnetics Society of Japan 1994

Journal: :Electrochimica Acta 2021

We report on the generation of electrochemiluminescence (ECL) from luminol and hydrogen peroxide (H2O2) in alkaline aqueous solution entirely pure conducting polymer (CP) films. Poly(3,4-ethylenedioxythiophene) (PEDOT) polypyrrole (PPy) films prepared by constant current electrolysis were used as bipolar electrodes (BPEs) to drive ECL emission a wireless mode with aid electrochemistry. A common...

2013
Xin Chen Li-Li Xing Yu-Hai Tang Guang-Bin Zhang

A rapid and sensitive flow-injection chemiluminescence (CL) method for the determination of glipizide was developed on the basis of finding that glipizide can enhance the CL intensity of the luminol-K3Fe(CN)6 system. In optimum condition, the increased CL intensity was directly proportional to the concentration of glipizide in the range from 4.0×10-8 g/mL to 1.0×10-6 g/mL and the detection limi...

Journal: :Chemical communications 2011
Huan Niu Ruo Yuan Yaqin Chai Li Mao Yali Yuan Yaling Cao Ying Zhuo

An immunosensor based on the electrochemiluminescence (ECL) of luminol was proposed by coupling enzymatic reaction to in situ generate coreactant with Pd nanoparticles as catalyst for the ECL reaction, which was successfully applied for the ultrasensitive detection of α-1-fetoprotein with a low detection limit of 33 fg mL(-1).

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید