Wavelength selection is a critical step for producing better prediction performance when applied to spectral data. Considering the fact that the vibrational and rotational spectra have continuous features of spectral bands, we propose a novel method of wavelength interval selection based on random frog, called interval random frog (iRF). To obtain all the possible continuous intervals, spectra ...
Variable (or wavelength) selection plays an important role in the quantitative analysis of near-infrared (NIR) spectra. A modified method of uninformative variable elimination (UVE) was proposed for variable selection in NIR spectral modeling based on the principle of Monte Carlo (MC) and UVE. The method builds a large number of models with randomly selected calibration samples at first, and th...
A new Fourier Transform-Infra Red (FT-IR) spectrometric method was developed for assaying hydrochlorothiazide (HCT) and enalapril maleate (ENM) in binary solid pharmaceutical formulations. Multivariate Partial Least Squares (PLS) method was used for calibration of derivative spectral data. Acetonitrile was used as solvent due to its spectral tran...
Quantitative structure-activity relationship (QSAR) analysis has been carried out with a series of 107 anti-HIV HEPT compounds with antiviral activity, which was performed by chemometrics methods. Bi-dimensional images were used to calculate some pixels and multivariate image analysis was applied to QSAR modelling of the anti-HIV potential of HEPT analogues by means of multivariate calibration,...
Application of multivariate curve resolution alternating least squares (MCR-ALS), for the resolution and quantification of different analytes in different type of pharmaceutical and agricultural samples is shown. In particular, MCR-ALS is applied first to the UV spectrophotometric quantitative analysis of mixtures of commercial steroid drugs, and second to the near-infrared (NIR) spectrophotome...
When an instrument response is measured over a period of time changes in the signal intensity can occur. If this happens following the calibration of an instrument, in this instance using a multivariate model, subsequent use of the calibration model will most probably produce erroneous results, posing severe restrictions on the successful application of such models. However, it is possible to s...
Three methods are presented for simultaneous determination of ibuprofen and paracetamol without previous separation. The first method depends on first derivative UV spectrophotometry, with zero-crossing measurement. The first derivative amplitudes at 230 and 290 nm were selected for the assay of ibuprofen and paracetamol, respectively. The second method depends on first derivative of the ratio-...