نتایج جستجو برای: poly eriochrome black t modified electrode
تعداد نتایج: 1196306 فیلتر نتایج به سال:
It has been shown earlier that the DNA double helix is opened due to a prolonged contact of the DNA molecule with the surface of the mercury electrode. At neutral pH, the opening process is relatively slow (around 100 s), and it is limited to potentials close to -1.2 V (against SCE). The opening of the double helix has been explained by strains in the DNA molecule due to strong repulsion of the...
-Clay-modified electrode research indicates that adsorbed complexes are electroactive if the adsorption sites are clay edges. Interlayer adsorbed complexes may be electroactive ifa charge shuttle is added or if interlayer swelling is large. Conductivity of the film towards anionic species depends upon the swelling of the clay, which depends on the electrolyte concentration and speciation. The d...
Poly(vinylferrocenium) perchlorate-poly(3,3’-diaminobenzidine) (PVFClO4 -PDAB) composite film was synthesized electrochemically for the first time on Pt disc electrode in a dichloromethane solution containing poly(vinylferrocene) (PVF) polymer, 3,3’-diaminobenzidine (DAB) monomer and tetrabutylammonium perchlorate as supporting electrolyte. This modified electrode was characterized using cyclic...
Poly(anthranilic acid) Nanorods: Synthesis, Characterization and Electrochemical Sensing Properties†
Nanostructured poly(anthranilic acid) was synthesized by oxidative polymerization using potassium persulfate as an oxidant and malonic acid (MA) as dopant. The synthesized polymer was characterized by various techniques. The structure of poly(anthranilic acid) was confirmed by FT-IR spectroscopy. The UV-Vis spectra of poly(anthranilic acid) shows π-π* and inter-ring charge transfer bands. The s...
برهمکنش پورفیرازین کاتیونی تتراکیس(n,n,n,n -4,3-تتراپیریدینو) روی(ii) (zn(tmtppa))با پلی نوکلئوتیدهای سنتزی: poly[d(g-c)]2 و poly[d(a-t)]2 و dna غده تیموس گوساله در بافر فسفات 5/7 میلی مولار با ph 2/7 با استفاده از تکنیک های اسپکتروسکوپی جذب نوری و فلورسانس مطالعه شده است. کاهش جذب بیشتر از % 40 در طیف uv-vis پورفیرازین به دلیل برهمکنش با هر دو پلی نوکلئوتیدهای poly[d(g-c)]2 و poly[d(a-t)]2 م...
The development of integrated microsystems capable of interrogation, characterization and sorting of mammalian cells is highly significant for further advancement of point-of-care diagnostics and drug discovery fields. The present study sought to design a novel strategy for releasing antibody-bound cells through electrochemical disruption of the underlying antibody (Ab) layer. A microsystem for...
tin(ii)-ion-selective electrode consisting of dibenzo-18-crown-6 (db18c6) as an ionophore inpvc matrix was developed. the influences of membrane composition, selectivity, response time,reversibility and temperature on the electrode performance were investigated. the electrodeshowed a near nernstian response for sn2+ ions over a concentration range from 1.0× 10-6 – 1.0× 10-2 m with a slope of 27...
برهمکنش پورفیرازین کاتیونی تتراکیس(n,n,n,n 3و4-تتراپیریدینو) کبالت(ii) (co(tmtppa))با پلی-نوکلئوتیدهای سنتزی: poly(g-c) و poly(a-t) و dna غده تیموس گوساله در بافر فسفات 5/7 میلی مولار با ph 2/7 با استفاده از تکنیک های اسپکتروسکوپی جذب نوری و فلورسانس مطالعه شده است. کاهش جذب و جابجایی قرمز در طول .موج طیف uv-vis پورفیرازین به دلیل برهمکنش با هر دو پلی نوکلئوتیدهای poly(g-c) و poly(a-t) مشاهده...
This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...
potentiometric investigation on {h2o+nano3+peg1500} mixtures were made at t=308.15k, using electrochemical cells with two ion-selective electrodes, (na+ glass) as the cation ion-selective electrode against (no3- solvent-polymer pvc) as the anion ion-selective electrode. the mean ionic activity coefficients of nano3 were measured at different concentrations of nano3 and peg. maximum concentrati...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید