نتایج جستجو برای: thermal and fast equivalent dose

تعداد نتایج: 16944698  

Journal: :iranian journal of radiation research 0
j.g. fantidis department of electrical engineering, technological education institute of eastern macedonia and thrace, saint loucas, kavala, greece a. antoniadis cardiovascular division, brigham and women's hospital, harvard medical school, boston, usa

background: a boron neutron capture therapy (bnct) facility, based on a dt neutron generator, with the final goal to find out a potential, alternative, solution to existing bnct treatment facilities which are based on nuclear reactors is examined. materials and methods: with the aim of the mcnp4b monte carlo code different beam-shaping assembly (bsa) configurations were considered. lead was sel...

Journal: :Optics express 2009
Wei Dai Qing Yang Fuxing Gu Limin Tong

Room temperature operating thermal detection for mid-infrared light based on ZnO subwavelength wires has been demonstrated. Electric resistance in ZnO wires increases linearly with the intensity of incident light. Noise equivalent power (NEP) of 5.8 microW/Hz(1/2) (at 1 kHz) with typical response times as fast as 1.3 ms is obtained at 10.6-microm wavelength. The sensitivity and response time of...

Journal: :iranian journal of radiation research 0
s. sathiyan department of radiation physics, kmio, bangalore, india m. ravikumar department of radiation physics, kmio, bangalore, india r. ravichandran national oncology center, royal hospital, muscat, oman

background: to evaluate the risk involved, there is need to know the quantum of personnel exposures in whole service. dose reports from an oncology centre over 7 block periods, 5 years each from 1979 till 2013 are analyzed. materials and methods: personnel monitoring (pm) reports till 1990s with film badges and later thermoluminescent (tl) badges (caso4.dy) were evaluated. 35 years total servic...

Journal: :journal of biomedical physics and engineering 0
n singh n k painuly l n chaudhari a chairmadurai t verma d shrotiya

aims: the aim of the present work is (1) to evaluate dose calculation accuracy of two commonly used algorithms for 15 mv small photon fields in a medium encompassing heterogeneity and (2) compare these results with measured results obtained using gafchromic film ebt2. materials and methods: authors employed kailwood (pinus wallichiana) to mimic lung. briefly, seven kailwood plates, each measuri...

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

A. Shakeri-zadeh P. Shokrani S. Haghjooy Javanmard S. Pandesh

Introduction: Photothermal therapy using gold nanoshells is one of cancer therapy methods. Gold nanoshells generally consist of a silica core and a thin gold shell. Fe3O4@Au core-shell can be used for magnetic targeted therapy. The objective of this study was investigation of the photothermal effects of magnetically targeted Fe3O4@Au NPs and NIR laser irradiation on model of me...

Journal: :iranian journal of radiation research 0
k. kant dept. of physics, k l mehta dayanand college for women, faridabad, haryana, india-121 001 s.k. chakarvarti dept. of applied physics, n.i.t., kurukshetra, haryana, india -136 119

background: in this study, measurement of indoor radon and its progeny levels was carried out in gas turbine power station in haryana ( india ), where natural gas is used as fuel. for comparison, the results of a study carried out in thermal power plant in haryana are also presented. radon being a ubiquitous air pollutant has global impact and its monitoring in the environment at work places is...

ژورنال: سلامت کار ایران 2013

  Background and Objective : Noise is considered as a common occupational health hazard in a wide range of occupational settings including oil and gas industries and related companies. This research aimed to assess the environmental noise and personal exposure in a petrochemical plant.   Method: First, environmental noise measurement was performed as recommended by ISO9612 (1997) and next, shor...

Behzad Mohsenzadeh, Fereshte Rahmani Leila azimi Mohammad Reza Deevband, Zeinab Kaveh

Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...

Journal: :Health physics 1997
J D Cossairt N L Grossman E T Marshall

Neutrinos are present in the natural environment and are also produced by particle accelerators. A recent hypothesis has also been proposed that asserts that ionizing radiation due to neutrinos from certain astronomical events may have led to the extinction of some biological species. Thus, it is of interest to be able to estimate the dose equivalent due to these weakly interacting particles. P...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید