نتایج جستجو برای: differential transformer

تعداد نتایج: 295999  

The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...

2014
Saurabh Shrivastava Ashfaque Khan Amita Mahor

Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...

Journal: :The Review of scientific instruments 2007
Mingsen Guo K H Lam S Wang K W Kwok Helen L W Chan X Z Zhao

In this study, a modified disk-shaped multiple-output piezoelectric transformer operated at the fundamental radial vibration mode has been presented. A derived equivalent circuit for the multioutput piezoelectric transformer was used to analyze the performance. Two piezoelectric transformers, a symmetrically electroded piezoelectric transformer with dual outputs and an asymmetrically electroded...

2013

For flyback coverters, the transformer is the most important factor that determines the performance such as the efficiency, output regulation and EMI. Contrary to the normal transformer, the flyback transformer is inherently an inductor that provides energy storage, coupling and isolation for the flyback converter. In the general transformer, the current flows in both the primary and secondary ...

2013
Xin-Huai Wang Li Zhang Yin Xu Yan-Fu Bai Cheng Liu Xiaowei Shi

In this paper, a compact tri-band impedance transformer by utilizing stubbed coupling line for matching a load at three arbitrary frequencies is proposed. The transformer is composed of two parts, and each part is constructed from parallel-coupled transmission lines. Two structures with different configurations of the proposed transformer have been given and analyzed. Then, the close-form equat...

Journal: :International Journal of Engineering, Science and Technology 2010

Journal: :journal of ai and data mining 2013
mehdi hajian asghar akbari foroud

the aim of this paper is to extend a hybrid protection plan for power transformer (pt) based on mra-ksir-ssvm. this paper offers a new scheme for protection of power transformers to distinguish internal faults from inrush currents. some significant characteristics of differential currents in the real pt operating circumstances are extracted. in this paper, multi resolution analysis (mra) is use...

2001
T. G. Engel

The analysis, design, and operation of high-voltage, transformer-coupled LC vector inversion generators are presented and discussed. The transformer-coupled LC inversion generator is easy to construct and, compared with Marx-type generators and conventional LC vector inversion generators, requires only one inversion switch, independent of the number of voltage multiplication stages. The transfo...

2008
Xiao-Yuan Chen Jian-Xun Jin

⎯With the improvement of high temperature superconductor (HTS) practical performance, research and development concerning the applications of HTS transformers have been progressed actively worldwide. This paper provides a comprehensive summary on various HTS transformers, and studies the design of a single-phase 10 kVA (220V/24V) HTS transformer prototype to verify HTS for practical transformer...

Journal: :The Transactions of The Korean Institute of Electrical Engineers 2011

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید