نتایج جستجو برای: fluid pressure

تعداد نتایج: 603318  

Fazel Almasi, Mohsen Sari Morteza Chaji Somayeh Salari

Effects of different levels of cadmium (0.1, 1, 2, 4, 8, 16, 32, 64, 128, 256 mg/l of culture medium) were evaluated using gas production technique. In the glass vials used to measure gas production 30 mg of buffered rumen fluid (2:1 ratio of rumen fluid: buffer) poured in glass and cultured at 38.6 temperature. Volume and pressure of produced gas were measured with syringes and digital pressur...

2010
Moritz Wyler von Ballmoos Jukka Takala Margareta Roeck Francesca Porta David Tueller Christoph C Ganter Ralph Schröder Hendrik Bracht Bertram Baenziger Stephan M Jakob

INTRODUCTION Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure. METHODS Fifteen cardiac surgery patients with a history of increased pulmonary artery pressure (mean pressure, 27 +/- 5 mm H...

The evaluation of a free fluid surface in a porous medium has several mathematical applications that are important in industries using molds, particularly in the fluid injection process. The vacuum-assisted resin transfer molding (VARTM) process is a promising technology in the primary composite industry. An accurate computational simulation of the VARTM process would be a cost-effective tool i...

2015
Uttio ROY CHOWDHURY Michael P. FAUTSCH

Retrospective and prospective studies looking at the role of cerebrospinal fluid pressure (CSFP)/intracranial pressure (ICP) have stimulated new theories and hypotheses regarding the underlying causal events for glaucoma. Most recently, studies supporting a low CSFP/ICP as a risk factor for glaucoma have been published. This review summarizes the current understanding of CSFP/ICP and its potent...

Journal: :Stroke 1973
T Iwabuchi K Watanabe T Kutsuzawa K Ikeda T Nakamura

Lactate in the Cerebrospinal Fluid and Pressure-Flow Relationships in Canine Cerebral Circulation • In 11 dogs, lactate and pH in the cerebrospinal fluid and in the arterial and the venous blood were measured during stepwise reductions of the arterial blood pressure by controlled bleeding. Increase in lactate and decrease in pH of the cerebrospinal fluid occurred with lowering of the mean arter...

F. Ashori H. Maddah M. Aghili R. Aghayeri,

In this work, the characteristics of flow and heat transfer of a fluid containing nano particles of aluminum oxide with the water volume fraction (0.1-0.2-0.3)(V/V) percent of the reports. The overall heat transfer coefficient, heat transfer and the average heat transfer fluid containing nano water - aluminum oxide in a horizontal double pipe counter flow heat exchanger under turbulent flow con...

Journal: :Hypertension 1992
A C Guyton

The human body has multiple blood pressure control mechanisms, each of which serves a special and usually different role in pressure regulation. The nervous pressure controllers usually react within seconds and prevent major rapid changes in pressure when acute extraneous forces act on the circulatory system. Then, within minutes to hours, several intermediately acting pressure controllers beco...

Journal: :The Journal of Experimental Medicine 1946
Philip D. McMaster

Means have been described for the study of pressure conditions in normal and pathological skin of living human beings and mice. The true pressure in normal skin cannot be measured directly by any of the means hitherto described, because there is insufficient free fluid to make manometric determinations. However, for practical purposes, the intracutaneous pressure has been approximately estimate...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید