نتایج جستجو برای: glass membrane electrode
تعداد نتایج: 516981 فیلتر نتایج به سال:
in order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (npdbh) was used as an ionophore. this electrode responds to sr (ii)ion with a sensitivity of 28.2 ± 0.5 mv/decade over the range 1.0 x 10-6 to 1.0 mat ph 3.0-10.0. thelimit of detection was 2.4 x 10-7 m. the influences of membrane composition, the ph of the t...
a physic-mathematical model has been developed that is suitable for biosensors incorporating membranes and bisubstrate enzymes. the set of equations regarding the transport of reactants across the membrane, the bisubstrate enzymatic reaction, back diffusion of reactants and reaction products, are written down and simultaneously solved and transient response of the electrode is determined as a f...
This paper reports the performance of nickel oxide based electrode in alkaline anion exchange membrane water electrolysis. The membrane used is polystyrene based alkaline membrane and the electrode used is Nickel as cathode and Nickel oxide as anode. The electrochemical activity of the Nickel oxide is high compared to uncoated electrode. The AWE membrane electrode gave high current density at 3...
TYPES OF MELTS From the practical viewpoint, melts may be classified according to melting points which may limit the available techniques. The lowest melting, with working temperatures up to 250°, are typified by the LiNO3—NaNO3— KNO3 eutectic, NaNO3—KNO3 eutectic, LiClO4, and ammonium formate. With these solvents it is possible to use the dropping mercury electrode, or hanging mercury drop ele...
The use of an optically thin indium-tin-oxide (ITO) electrode is presented for an optoelectric biosensor simultaneously recording optical images and microimpedance to examine time-dependent cellular growth. The transmittance of a 100 nm thick ITO electrode layer is approximately the same as the transmittance of a clean glass substrate, whereas the industry-standard Au(47.5 nm)/Ti(2.5 nm) electr...
A multibarreled glass-coated tungsten microelectrode suitable for single-unit recording and iontophoresis in chronically behaving animals is described. The microelectrode was stiff enough to pass through the dura matter of behaving monkeys, and can be applied as a microiontophoretic electrode. The electrode is easy to build and usable in stabilized conditions after repeated penetrations.
Current methods for recording field potentials with tungsten electrodes make it virtually impossible to use the same recording electrode also as a lesioning electrode, for example for histological confirmation of the recorded site, because the lesioning procedure usually wears off the tungsten tip. Therefore, the electrode would have to be replaced after each lesioning procedure, which is a ver...
An assessment of the sensitivities of the critical parameters in the ASTM D6423 documentary standard method for the measurement of pHe in (bio)ethanol has been undertaken. Repeatability of measurements made using the same glass electrode and reproducibility between different glass electrodes have been identified as the main contributors to the uncertainty of the values produced. Strategies to r...
In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید