adolescents and young adults and their problems is an issue whose importance is obvious to anyone because youth are the founders of our countrys future and requires proper planning to be on leisure. given the importance of leisure,this study to investigate needs assessment and planning how adolescents and young adults spend their leisure time in urban of case study of high school girls and boys...
introduction low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. dosimetric characteristics of a new irseed 125i brachytherapy source have been determined using the lif thermoluminescent dosimeter (tld) chips. materials and methods dose rate constant, radial dose function, and anisotropy function around the irseed 125i so...
An extensive set of measured data was developed for the purpose of verifying the accuracy of a photon dose-calculation algorithm. Dose distributions from a linear accelerator were measured using an ion chamber in a water phantom and thermoluminescent dosimeters in a heterogeneous anthropomorphic phantom. Test cases included square fields, rectangular fields, fields having different source-to-su...
The delivery of accurate proton dose for clinical trials requires that the appropriate conversion function from Hounsfield unit (HU) to relative linear stopping power (RLSP) be used in proton treatment planning systems (TPS). One way of verifying that the TPS is calculating the correct dose is an end-to-end test using an anthropomorphic phantom containing tissue equivalent materials and dosimet...
BACKGROUND AND PURPOSE Radiosurgery is a non-invasive treatment for many spinal tumors. Sacral radiosurgery, however, requires invasive fiducial marker insertion to target and track the tumor's position. We present preliminary clinical results and phantom accuracy measurements of sacral radiosurgery using fiducial-free alignment based on vertebral anatomy distant to tumor location. MATERIALS ...
PURPOSE This study aims to investigate the factors that reduce fetal dose in pregnant patients with breast cancer throughout their radiation treatment. Two main factors in a standard radiation oncology center are considered as the treatment planning systems (TPSs) and simple shielding for intensity modulated radiation therapy technique. MATERIALS AND METHODS TPS factor was evaluated with two ...
Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...
BACKGROUND AND PURPOSE The Medical Physics Division of the Portuguese Physics Society (DFM_SPF) in collaboration with the IAEA, carried out a national auditing project in radiotherapy, between September 2011 and April 2012. The objective of this audit was to ensure the optimal usage of treatment planning systems. The national results are presented in this paper. MATERIAL AND METHODS The audit...
In this study, we compared the amount of lung tissue irradiated when respiratory gating was imposed during expiration with the amount of lung tissue irradiated when gating was imposed during inspiration. Our hypothesis was that the amount of lung tissue spared increased as inspiration increased. Computed tomography (CT) image data sets were acquired for 10 patients who had been diagnosed with p...