نتایج جستجو برای: planning target volume

تعداد نتایج: 886017  

2016
Henry Kleiner Matthew B. Podgorsak

BACKGROUND The purpose of the study was to analyse the dosimetric differences when using 10 MV instead of 6 MV for VMAT treatment plans for post-prostatectomy irradiation of the prostate bed. METHODS AND MATERIALS Ten post-prostatectomy prostate bed irradiation cases previously treated using 6 MV with volumetric modulated arc therapy (VMAT) were re-planned using 10 MV with VMAT. Prescription ...

2015
Alexandru Nicolae Melanie Davidson Harry Easton Joelle Helou Hima Musunuru Andrew Loblaw Ananth Ravi

BACKGROUND The objective of this study was to evaluate a novel prostate endorectal immobilization system (EIS) for improving the delivery of hypofractionated Stereotactic Ablative Body Radiotherapy (SABR) for prostate cancer. METHODS Twenty patients (n = 20) with low- or intermediate-risk prostate cancer (T1-T2b, Gleason Score < 7, PSA ≤ 20 ng/mL), were treated with an EIS in place using Volu...

2015
Marie Huss Pierre Barsoum Ernest Dodoo Georges Sinclair Iuliana Toma‐Dasu

Stereotactic radiosurgery using Gamma Knife (GK) or linear accelerators has been used for decades to treat brain tumors in one fraction. A new positioning system, Extend™, was introduced by Elekta AB for fractionated stereotactic radiotherapy (SRT) with GK. Another option for fractionated SRT is advanced planning and delivery using linacs and volumetric modulated arc therapy (VMAT). This projec...

Journal: :Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology 2013
James C L Chow Runqing Jiang

AIM This study compared the dosimetric impact between prostate IMRT and VMAT due to patient's weight loss. BACKGROUND Dosimetric variation due to change of patient's body contour is difficult to predict in prostate IMRT and VMAT, since a large number of small and irregular segmental fields is used in the delivery. MATERIALS AND METHODS Five patients with prostate volumes ranging from 32.0 t...

2018
Saif Aljabab Balamurugan Vellayappan Eric Vandervoort Jamie Bahm Robert Zohr John Sinclair Jean‐Michel Caudrelier Janos Szanto Shawn Malone

PURPOSE The aim of this study is to compare the dosimetric differences between four techniques for spine stereotactic body radiotherapy (SBRT): CyberKnife (CK), volumetric modulated arc therapy (VMAT), and helical tomotherapy (HT) with dynamic jaws (HT-D) and fixed jaws (HT-F). MATERIALS/METHODS Data from 10 patients were utilized. All patients were planned for 24 Gy in two fractions, with th...

2012
Keiichi Nakagawa Satoshi Kida Akihiro Haga Yoshitaka Masutani Hideomi Yamashita Tsuyoshi Onoe Toshikazu Imae Kenichiro Tanaka Kuni Ohtomo Kiyoshi Yoda

We have proposed four dimensional (4D) digitally reconstructed radiography (DRR) for verifying a lung tumor position during volumetric modulated arc therapy (VMAT). An internal target volume (ITV) was defined based on two clinical target volumes (CTVs) delineated on maximum exhalation and maximum inhalation images acquired by 4D planning computed tomography (CT). A planning target volume (PTV) ...

Journal: :Medical physics 2014
J Cai K Wijesooriya S Benedict

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. Treatment planning of SBRT is characterized by precise target volume delineation, highly conformal dose distribution, sharp dose gradient outside the target volume, and meticulous tumor motion management. Stringent dose volume constraints of SBRT require the treatment planning to be highly personaliz...

2014
Olivier Riou Benjamin Serrano David Azria Benoit Paulmier Remy Villeneuve Pascal Fenoglietto Antonella Artenie Cécile Ortholan Marc Faraggi Juliette Thariat

BACKGROUND To assess the feasibility and benefit of integrating four-dimensional (4D) Positron Emission Tomography (PET) - computed tomography (CT) for liver stereotactic body radiation therapy (SBRT) planning. METHODS 8 patients with 14 metastases were accrued in the study. They all underwent a non-gated PET and a 4D PET centered on the liver. The same CT scan was used for attenuation correc...

Journal: :Journal of radiation research 2012
Munetaka Matoba Kiyotaka Oota Ichiro Toyoda Masataka Kitadate Naoto Watanabe Hisao Tonami

It is well known that significant variations in stomach size, shape, and respiratory motion lead to uncertainties in target localization during treatment for gastric lymphoma. In this study, the usefulness of 4D-CT for radiation planning of gastric MZBCL/MALT was evaluated. Treatment planning using 4DCT (plan A) and conventional planning with a uniform margin (plan B) were compared using dose v...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید