نتایج جستجو برای: slab head phantom
تعداد نتایج: 193829 فیلتر نتایج به سال:
A proposed method to obtain the dose for Computed Tomography was evaluated on long a phantom, made of polyethylene. This phantom is 600 mm large. Adopting an empirical characterized function , tendency asymptotical grow by increase scanning length can estimate in infinite single axial rotation x-ray tube. The curve estimated different clinical protocols: tension, pitch, head/body, and center/pe...
The purpose of this study was to develop coils for MR imaging of the head and neck region, with the aim of improving sensitivity and coverage. A head and neck phased array coil was constructed and compared with volume and temporomandibular joint surface coils for sensitivity and coverage in phantom studies. An algorithm was implemented to correct for the nonuniformity in the surface coil recept...
In present study, a mathematical model of the vehicle–floating slab track (FST) interaction is established to investigate the coupled behaviour of vehicle–track system. The FST is modelled as the double Euler -Bernoulli beam including the rail and slab. The railway vehicle is simplified as a multi-rigid-body model. The wheel–rail interface is treated using a nonlinear Hertzian contact model, co...
Kilovoltage (kV) cone beam computed tomography (CBCT) images suffer from a substantial scatter contribution. In this study, Monte Carlo (MC) simulations are used to evaluate the scattered radiation present in projection images. These predicted scatter distributions are also used as a scatter correction technique. Images were acquired using a kV CBCT bench top system. The EGSnrc MC code was used...
The Elekta Synergy is a radiotherapy treatment machine with integrated kilovoltage (kV) X-ray imaging system capable of producing cone beam CT (CBCT) images of the patient in the treatment position. The aim of this study is to assess the additional imaging dose. Cone beam CT dose index (CBDI) is introduced and measured inside standard CTDI phantoms for several sites (head: 100 kV, 38 mAs, lung:...
The main purpose of this work was to quantify patient organ doses from the two kilovoltage cone beam computed tomography (CBCT) systems currently available on medical linear accelerators, namely the X-ray Volumetric Imager (XVI, Elekta Oncology Systems) and the On-Board Imager (OBI, Varian Medical Systems). Organ dose measurements were performed using a fiber-optic coupled (FOC) dosimetry syste...
A comprehensive end-to-end test for head and neck IMRT treatments was developed using a custom phantom designed to utilize multiple dosimetry devices. Initial end-to-end test and custom H&N phantom were designed to yield maximum information in anatomical regions significant to H&N plans with respect to: (i) geometric accuracy, (ii) dosimetric accuracy, and (iii) treatment reproducibility. The p...
Correspondence to: Fábio Luiz Ferreira Scannavino Avenida 23, 0126 Centro 14781-343 Barretos, SP, Brasil Phone: +55-17-3322-1360 E-mail: [email protected] Received for publication: January 14, 2010 Accepted: June 16, 2010 Abstract Aim: The purpose of this study was to compare the effectiveness of a high-volume evacuation and a conventional intraoral suction system and aspirating tips for c...
Introduction: Nasopharyngeal carcinoma is one of the most common malignancies in the head and neck region and radiotherapy is its treatment of choice. In spite of the fact that it is widely used, due to the presence of many sensitive organs or tissues in this region, patients may suffer from a wide range of side effects. One such sensitive tissue is the spinal cord. If the absorbed dose to spin...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید