The CZT detector on the InFOCμS hard X-ray telescope is a pixellated solid-state device capable of imaging spectroscopy by measuring the position and energy of each incoming photon. The detector sits at the focal point of an 8m focal length multilayered grazing incidence X-ray mirror which has significant effective area between 20–40 keV. The detector has an energy resolution of 4.0 keV at 32 k...
Two detection systems for gas-liquid chromatography were compared for the identification of metabolic end products (short-chain organic acids) from anaerobic bacteria. Argon and flame ionization detectors were connected in series with inert argon as the carrier gas for analysis of 35 stock strains and 148 clinical isolates. There was an excellent correlation between the argon and flame ionizati...
A fire detector is the most important component in a fire alarm system. Herein, we present the feasibility of a highly sensitive and rapid response gas sensor based on metal oxides as a high performance fire detector. The glancing angle deposition (GLAD) technique is used to make the highly porous structure such as nanocolumns (NCs) of various metal oxides for enhancing the gas-sensing performa...
background: the poly-allyl diglycol carbonate (padc) detector is of particular interest for development of a fast neutron dosimeter. fast neutrons interact with the constituents of the cr-39 detector and produce h, c and o recoils, as well as (n, α) reaction. these neutron- induced charged particles contribute towards the response of cr-39 detectors. material and methods: electrochemical etchin...
This study aims at the experimental determination of the detector-specific 1D lateral dose response function K(x) and of its associated rotational symmetric counterpart K(r) for a set of high-resolution detectors presently used in narrow-beam photon dosimetry. A combination of slit-beam, radiochromic film, and deconvolution techniques served to accomplish this task for four detectors with diame...
The optimum design, construction, and use of the LIGO, VIRGO, or LAGOS gravitational radiation detectors depends upon accurate calculations of their sensitivity to different sources of radiation. Here I examine how to determine the sensitivity of these instruments to sources of gravitational radiation by considering the process by which data are analyzed in a noisy detector. The problem of dete...
The X-ray detector is the heart of a digital mammography system. Its improved characteristics of dynamic range and signal-to-noise ratio provide inherent advantages over screen-fi lm technology. Detector technologies used for digital mammography can be distinguished by the acquisition geometry into scanning or full-fi eld detectors, by energy conversion mechanism into phosphor-based and nonphos...
چکیده ندارد.
abstract venlafaxine, 1–[2–(dimethylamino)–1–(4–methoxyphenyl) ethyl]cyclohexanol hydrochloride is a novel non-tricyclic antidepressant. venlafaxine is a second generation antidepressant drug, has a neuropharmacologic profile distinct from that of existing antidepressants including tricyclic compounds, selective serotonin reuptake inhibitors and monoamine oxidase inhibitors. venlafaxine impart...
Response of the rotating-detector ellipsometer to incident partially polarized light," Appl.