نتایج جستجو برای: voltage harmonic mitigation

تعداد نتایج: 183849  

2012
Yash Pal A. Swarup B. Singh

In this paper, a simplified control algorithm based on unit vector template generation (UVTG) is proposed for a stardelta supported three-phase four-wire (3P-4W) unified power quality conditioner (UPQC) topology for the improvement of different power quality problems. Different topologies reported in literature for 3P-4W UPQC use active compensation for the mitigation of source neutral current ...

جوادی, شهرام, حسینی علی‌آبادی, محمود, فشکی فراهانی, حسن, پرکار, سیامک,

In this paper a new topology is introduced for three-phase inverter that includes a multi-level module, a three-phase inverter bridge and middle levels selection unit. The main advantage of proposed topology is using fewer switches and diodes to reach the maximum level of output voltage. The structure consists of a single-phase multilevel module; three bidirectional switches and a three-phase i...

2010
T. DEVARAJU

Custom Power devices like Dynamic voltage restorer and STATCOM are normally employed as a solution for mitigation of power quality problems like voltage sag and swell. In this paper new voltage sag compensators based on an autotransformer and an IGBT switched by PWM technique and Hysteresis Voltage Control (HVC) method are compared. These two schemes are able to recognize the voltage sag condit...

2014
Renjie Hu Guiping Yi Wei Jiang Huichun Huang

Industrial Static Var Generator (SVG) is typically applied at or near the load center to mitigate voltage fluctuation, flicker, phase unbalance, non-sine distortion or other load-related disturbance. Special attention is paid to the influence of grid voltage quality on SVG current, the non-sine distortion and unbalance of grid voltage causes not only the AC current distortion and unbalance but ...

2011
Swati Devabhaktuni Jayaram Kumar

This paper deals with the performance analysis of static compensator (STATCOM) based voltage regulator for self excited induction generators (SEIGs) supplying balanced/unbalanced and linear/non linear loads. A threephase insulated gate bipolar transistor (IGBT) based current controlled voltage source inverter (CC-VSI) known as STATCOM is used for harmonic elimination. It also provides the requi...

2007
Aamir Hanif Mohammad Ahmad Choudhry

-Dynamic Voltage Restorer (DVR) is a device used to mitigate voltage sags which are a significant power quality issue. This paper involves mathematical calculation for leading series voltage injection for mitigation of sags thereby achieving utility power factor improvement as well as power sharing between DVR and utility as per requirement and available distributed generation. Mathematical der...

2015
S. Alwin Dr. M. Marsaline Beno

This paper deals with an indirect current controlled shunt active power filter (SAPF) for improving power quality by reactive power compensation and harmonic filtering. The presence of harmonics and reactive power in the power source because it will cause additional power losses and malfunctions. The proposed APF is based on a voltage source inverter (VSI). The VSI is controlled by two loops, t...

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید