در این تحقیق بیم های فوتونی 6mv و 18mv شتابدهنده خطی پزشکیvarian clinac 2100c/d توسط کد مونت کارلوی mcnp4c شبیه سازی شده و منحنی های درصد دز عمقی و پروفایل های دز حاصل از شبیه سازی و اندازه گیری تجربی در فانتوم آب ptw مقایسه گشته اند. اجزای سر شتابدهنده که مدل شده اند شامل هدف، کولیماتور اولیه، پنجره خروجی، فیلتر مسطح کننده، کولیماتورهای ثانویه و صفحه مایلار می باشند. پس از سنجش صحت مدل در میدا...
conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...
Introduction: The dosimetry of the brachytherapy sources is performed in the water source medium according to protocol TG-43U1. To achieve a resonable results on treatment, the use of the water material for all body tissues can be one of the faulty sources in delivering the correct dose to the tumor. Thus, we have focused on the dosimetry parameters in fat density 0.95 gr/cm3 and the muscle wit...
سرطان یکی از عواملی است که در جهان امروز موجب مرگ انسان ها می شود، هرساله بیش از 10 میلیون نفر به علت سرطان می میرند. براکی تراپی نوعی پرتودرمانی خاص می باشد که در آن از پرتوهای یونساز برای درمان سرطان و کنترل تکثیر سلول های سرطانی بدخیم استفاده می شود و می توان در آن مقدار مناسب تابش را برای بافت انتخاب نمود. رساندن دوز تابش موثر به سلول های سرطانی، بافت های سالم اطراف تومور را به چالش بزرگی و...
درمان توسط گیر اندازی نوترون به وسیله بور یا boron neutron capture therapy(bnct) یکی از روشهای مورد توجه در درمان بعضی سرطانها از جمله تومورهای مغزی به نام گلیوبلاستوما، است. در این روش درمان، ابتدا بور به صورت یک ترکیب خاص که به وسیله مواد تومور دوست نشاندار شده است درون تومور متمرکز میشود، سپس یک باریکه از نوترونهای فوق حرارتی با انرژی و شدت مناسب بر روی منطقه تومور تابانده میشود. انرژی...
Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
Introduction: Sentinel lymph node biopsy (SLNB) is a standard surgical technique to identify sentinel lymph node (SLN) for the staging of early breast cancer. Nowadays, two methods are used for the identification of SLN: blue dye method aiding visually and radioactive dye using gamma detector. A wide range of gamma probe systems with different design and performance are used in...
background: prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. to study the lung absorbed dose in radiotherapy with small fields,...
background: lead-based radiation shields are widely used in radiology departments to protect both workers and patients from any unnecessary exposure to ionizing radiation. recently there has been a great deal of concern expressed about the toxicity of lead. human lead toxicity is well documented. in that light, production of environmentally-friendly lead-free radiation shields with less weight ...