نتایج جستجو برای: bladder and rectum dose
تعداد نتایج: 16879822 فیلتر نتایج به سال:
Pelvic exanteration is used in the treatment of several pelvic cancers, including those of the rectum, uterus, and bladder. We report the first case of robotic pelvic exanteration for the treatment of symptomatic prostate cancer involving the rectum and bladder. A six-port transperitoneal robotic approach was used. Bilateral extended lymphadenectomy up to the inferior mesenteric artery was perf...
Aim Since anatomical and geometric variations occur with every fraction, planning, and dose optimization is necessary for every fraction of high-dose rate intracavitary brachytherapy of carcinoma cervix. In this study, we have tried to quantify the differences in doses to organs at risk (OAR) for each fraction of brachytherapy. Methods and Materials One hundred and seventy computed tomography...
PURPOSE Intensity modulated radiation therapy (IMRT) compensation based on 3D high-dose-rate (HDR) intracavitary brachytherapy (ICBT) boost technique (ICBT + IMRT) has been used in our hospital for advanced cervix carcinoma patients. The purpose of this study was to compare the dosimetric results of the four different boost techniques (the conventional 2D HDR intracavitary brachytherapy [CICBT]...
BACKGROUND Our research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the PTV-parameters influencing these damages and changes in antitumor immune response. METHODS We analyzed 197 prostate cancer patients undergoing 3...
PurposeThe purpose of this study is to compare the predicted rate local control and bladder rectum toxicity rates for image-guided adaptive brachytherapy plans using a tandem ovoid (T/O) applicator versus simulated hybrid intracavitary/interstitial ring with needles (T/R + N) patients locally advanced cervical cancer (LACC).Methods MaterialsPatients ≥ FIGO Stage IIB treated T/O from single inst...
Tolerance and efficacy of preoperative intracavitary HDR brachytherapy in IB and IIA cervical cancer
PURPOSE The aim of this work is to analyze the efficacy and tolerance of preoperative intracavitary HDR brachytherapy (HDR-BT) in patients with IB and IIA cervical cancer. MATERIAL AND METHODS 139 patients with cervical cancer IB-IIA with preoperative HDR-BT, out of which 60 patients with cervical cancer IB (43.2%) and 79 with IIA (56.8%) were treated since 1996 to 2002. In preoperative BT to...
BACKGROUND To make a radiobiological comparison, for high risk prostate cancer (T3a, PSA > 20 ng/ml or Gleason > 7) of two radiotherapy treatment techniques. One technique consists of a treatment in three phases of the pelvic nodes, vesicles and prostate using a conventional fractionation scheme of 2 Gy/fraction (SIMRT). The other technique consists of a treatment in two phases that gives simul...
This study reviewed prostate volumetric-modulated arc therapy (VMAT) plans with intensity-modulated radiotherapy (IMRT) plans after prostate IMRT technique was replaced by VMAT in an institution. Characterizations of dosimetry and radiobiological variation in prostate were determined based on treatment plans of 40 prostate IMRT patients (planning target volume = 77.8-335 cm(3)) and 50 VMAT pati...
PURPOSE An evaluation of CT plan data, using cylinder applicators, in fractionated HDR treatments of cervical cancers has been investigated in this clinical study. Critical and statistical analysis of the data, for each patient and fraction, for plan dose, doses for bladder and rectum have been enumerated and reported. Plans were done for each patient, following CT scans after insertion of the ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید