نتایج جستجو برای: glass membrane electrode

تعداد نتایج: 516981  

Journal: :Clinica chimica acta; international journal of clinical chemistry 1970
L A Pioda W Simon H R Bosshard C H Curtius

The potassium-selective glass membranes like KAS,,_, and NAS,,_, are approx. IO times more sensitive to K+ than to Na +lp3. Since the concentration ratio of Na+/K+ in blood serum is around 35-40 and since there is at best a K+ over Naf selectivity in glass electrodes of IO, a separate measurement of the Na+ concentration is needed to correct the reading of the K+ sensor 4. Because of the depend...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

2007
William E. Mustain Hyea Kim Shruti Prakash Johanna Stark Tyler Osborn Paul A. Kohl

Thin-film electrodes for a low-power direct methanol fuel cell DMFC were prepared by incorporating carbon-supported Pt nanoparticles Pt/C into a silicon dioxide glass matrix. The SiO2 matrix was prepared via a sol-gel technique where tetraethyl orthosilicate TEOS was hydrolyzed by H2O in the presence of methanol. The Pt/C was stirred into the sol and the resulting mixture was applied to a glass...

Journal: :Circulation research 1964
M LAVALLEE

• Caldwell* was the first to measure directly the pH of large cells (crab muscle fibres) with a glass electrode. Kostyuk and Sorokina reduced considerably the dimensions of the glass electrode and measured directly the intracellular pH of sartorius muscle (frog). Finally, Carter first measured the intracellular pH of a mammalian cell (rat voluntary muscle) by means of a double-barreled microele...

Journal: :Gut 1987
G McLauchlan J M Rawlings M L Lucas R F McCloy G P Crean K E McColl

Three pH electrodes in clinical use were examined--(1) antimony electrode with remote reference electrode (Synectics 0011), (2) glass electrode with remote reference electrode (Microelectrodes Inc. MI 506) and (3) combined glass electrode with integral reference electrode (Radiometer GK2801C). In vitro studies showed that both glass electrodes were similar and superior to the antimony electrode...

2011
Yukihisa Okumura Tohru Ohmiya Toshiki Yamazaki

Cell-sized lipid bilayer membrane vesicles (giant vesicles, GVs) or semi-vesicles were formed from egg yolk phosphatidylcholine on a platinum electrode under applied electric voltage by electroformation. Micromanipulation of the semi-vesicle by first pressing its membrane with a glass microneedle and then withdrawing the needle left a GV in the interior of the vesicle. During the process, an aq...

Journal: :journal of physical & theoretical chemistry 2005
m. aghaie m. giahi h. aghaie m. pournaghdy

the preparation of polymer membrane selective to iron(ii) ion and its application to ion-selectiveelectrode is reported here. pvc membrane contains iron–selective n-phenylaza-15-crown-5 asionophore. the membrane electrode is highly selective to iron(ii) ion and exhibit good linearresponse over a wide concentration range of 1.0 × 10-2 to 1.0 × 10-6 m with nernstian slope of29.2 ± 0.6 mv per deca...

Journal: :The Journal of General Physiology 1965
W. J. Adelman F. M. Dyro J. Senft

Methods Isolated and cleaned squid giant axons were internally perfused by a modification of the method of Adelman and Gilbert (1964) and Adelman and Fok (1964). A chemically driven syringe (Sage Instruments) was directly connected to the axon interior through a small cut in one end by means of a 200,/ diameter glass cannula. The internal axoplasm was eroded away upon continuous internal fluid ...

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaie karim zare ali reza abedin mehran aghaie

a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...

Journal: :Biophysik 1973
D F Hülser D J Webb

The tip potential of Ling-Gerard glass microelectrodes changes upon insertion into cells and thus impedes the determination of the actual membrane potential. The lower the membrane potential of a cell, the larger will be the error due to this tip potential. However, as is demonstrated, a relationship exists between the tip potential of the electrode and the measured potential difference, which ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید