نتایج جستجو برای: homogeneous phantom
تعداد نتایج: 87222 فیلتر نتایج به سال:
An important step in the verification of the reliability of portal films as in vivo dosemeters is the evaluation of the agreement between exit dose profiles and optical density profiles measured on the portal film. To test the possibilities of a conventional portal film system in 60Co beams suitable for head and neck irradiation, we verified the agreement between relative exit doses (measured b...
Background: The heterogeneous composition of the human body presents numerous tissue types and cavities with widely differing radiologic properties. The aim of the present work was to develop a low cost homogeneous and heterogeneous phantom and the absorbed dose were measured by ionization chamber for different radiotherapy treatment techniques and compared with treatment planning syst...
It is possible to obtain a quality assurance (QA) of the dosimetry within a short time by using the new mathematical tools for a water phantom where dose measurements were made at two points only for a few square field sizes of the linear accelerator beam. The human body is not homogeneous. Water phantom makes it possible to create inhomogeneous phantoms by introducing blocks within it at suita...
Reconstruction algorithms for imaging fluorescence in near infrared ranges usually normalize fluorescence light with respect to excitation light. Using this approach, we investigated the influence of absorption and scattering heterogeneities on quantification accuracy when assuming a homogeneous model and explored possible reconstruction improvements by using a heterogeneous model. To do so, we...
Magnetic field distribution measurement and imaging of thin layers using magnetic resonance techniques on biological samples have been performed. The resultant image represents the magnetic susceptibility distribution in the sample. An NMR imaging method susceptible to the homogeneity of magnetic field Gradient Echo was used. Since the investigated physical or biological samples did not generat...
The purpose of this study is to investigate the optimal reference geometry for gamma camera calibration. Yet another question of interest was to assess the influence of the number of 3D Ordered Subsets Expectation Maximization (3D-OSEM) updates on activity quantification for SPECT imaging with 177Lu. The accuracy of 177Lu activity quantification was assessed both in small and in large objects. ...
We present an experimental validation of a kilovoltage (kV) X-ray source characterization model in an anthropomorphic phantom to estimate patient-specific absorbed dose from kV cone-beam computed tomography (CBCT) imaging procedures and compare these doses to nominal weighted CT-dose index (CTDIw) dose estimates. We simulated the default Varian on-board imager 1.4 (OBI) default CBCT imaging pro...
In this paper, we present a novel implementation of a dose calculation application, based on the GEANT4 Monte Carlo toolkit. Validation studies were performed with an homogeneous water phantom and an Alderson-Rando anthropomorphic phantom both irradiated with high-energy photon beams produced by a clinical linear accelerator. As input, this tool requires computer tomography images for automatic...
We show that in tilting perfect fluid cosmological models with an ultra-radiative equation of state, generically the tilt becomes extreme at late times and, as the tilt instability sets in, observers moving with the tilting fluid will experience singular behaviour in which infinite expansion is reached within a finite proper time, similar to that of phantom cosmology (but without the need for e...
Background and purpose: The human body is composed of various inhomogenous tissues with a variety of physical and radiological properties. These inhomogeneities could change isodose distributions, increase the probability of geometric errors, and eventually lead to missing of the target irradiation or incorrect isodose coverage in conformal radiation therapy (CRT) due to the uncertainties resul...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید