نتایج جستجو برای: osem reconstruction

تعداد نتایج: 123248  

2018
Charlotte A. Porter Kevin M. Bradley Eero T. Hippeläinen Matthew D. Walker Daniel R. McGowan

BACKGROUND Post-therapy SPECT/CT imaging of 90Y microspheres delivered to hepatic malignancies is difficult, owing to the continuous, high-energy Bremsstrahlung spectrum emitted by 90Y. This study aimed to evaluate the utility of a commercially available software package (HybridRecon, Hermes Medical Solutions AB) which incorporates full Monte Carlo collimator modelling. Analysis of image qualit...

Kazuhiko Himuro, Masayuki Sasaki, Shingo Baba, Shinichi Awamoto Yoshiyuki Umezu Yuji Tsutsui,

Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...

Journal: :Annals of nuclear medicine 2006
Takuya Morimoto Hiroshi Ito Akihiro Takano Yoko Ikoma Chie Seki Takashi Okauchi Katsuyuki Tanimoto Akira Ando Takahiro Shiraishi Taiga Yamaya Tetsuya Suhara

OBJECTIVES Both reconstruction algorithms, filtered backprojection (FBP) and ordered subsets expectation maximization (OSEM), are widely used in clinical positron emission tomography (PET) studies. Image reconstruction for most neurotransmission PET scan data is performed by FBP, while image reconstruction for whole-body [18F]FDG scan data is usually performed by OSEM. Although several investig...

Amin Zonoozi Kamran Aryana Mehdi Momennezhad, Mohsen Hajizadeh Seyed Rasoul Zakavi, Vahid Reza Dabbagh Kakhki,

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

2015
Julian MM Rogasch Ingo G Steffen Frank Hofheinz Oliver S Großer Christian Furth Konrad Mohnike Peter Hass Mathias Walke Ivayla Apostolova Holger Amthauer

BACKGROUND The maximum standardized uptake value (SUVmax) is a common clinical parameter for quantification in F18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT), but it is influenced by image reconstruction. The aim of this study was to analyze the association of SUVmax deviations related to point spread function (PSF) and time-of-flight (TOF) reconstruction w...

2009
Dan J Kadrmas

Iterative statistical reconstruction methods are becoming the standard in positron emission tomography (PET). Conventional maximum-likelihood expectation-maximization (MLEM) and ordered-subsets (OSEM) algorithms act on data which has been pre-processed into corrected, evenly-spaced histograms; however, such pre-processing corrupts the Poisson statistics. Recent advances have incorporated attenu...

2017
Navid Zeraatkar Arman Rahmim Saeed Sarkar Mohammad Reza Ay

OBJECTIVE S Various iterative reconstruction algorithms in nuclear medicine have been introduced in the last three decades. For each new imaging system, it is wise to select appropriate image reconstruction algorithms and evaluate their performance. In this study, three approaches of image reconstruction were developed for a novel desktop open-gantry SPECT system, PERSPECT, to assess their perf...

2018
T Rydén J Heydorn Lagerlöf J Hemmingsson I Marin J Svensson M Båth P Gjertsson P Bernhardt

BACKGROUND Full Monte Carlo (MC)-based SPECT reconstructions have a strong potential for correcting for image degrading factors, but the reconstruction times are long. The objective of this study was to develop a highly parallel Monte Carlo code for fast, ordered subset expectation maximum (OSEM) reconstructions of SPECT/CT images. The MC code was written in the Compute Unified Device Architect...

2017
Yuji Tsutsui Shinichi Awamoto Kazuhiko Himuro Yoshiyuki Umezu Shingo Baba Masayuki Sasaki

OBJECTIVES We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction. METHODS PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline ord...

Journal: :iranian journal of nuclear medicine 2004
seyed rasoul zakavi mohsen hajizadeh amin zonoozi mehdi momennezhad kamran aryana

introduction: motion of the patient during myocardial perfusion spect could potentially results in false perfusion defects. the effect of different reconstruction methods on these artifacts is not studied. clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. this study...