Advances in technology, the desire to minimize blood product transfusions, and concerns relating to inflammatory mediators have lead many practitioners and manufacturers to minimize cardiopulmonary bypass (CBP) circuit designs. The oxygenator and arterial line filter (ALF) have been integrated into one device as a method of attaining a reduction in prime volume and surface area. The instruction...
Arterial filters used in the extracorporeal circuit (ECC) have been shown to minimize cerebral injury by capturing particulate matter and microbubbles. We clinically use the Affinity NT oxygenator with an Affinity arterial filter attached ("Affinity system"). The new Affinity Fusion oxygenator ("Fusion") incorporates integrated arterial filtering. Our aim was to determine if the Fusion oxygenat...
There is little information showing the use of microporous polypropylene hollow fiber oxygenators during extra-corporeal life support (ECLS). Recent surveys have shown increasing use of these hollow fibers amongst ECLS centers in the United States. We performed a retrospective analysis comparing the Terumo BabyRx hollow fiber oxygenator to the Medtronic 800 silicone membrane oxygenator on 14 ne...
Objective Usually only FDA-approved oxygenators are subject of studies by the international scientific community. The objective of this study is to evaluate two types of neonatal membrane oxygenators in terms of transmembrane pressure gradient, hemodynamic energy transmission and gaseous microemboli capture in simulated cardiopulmonary bypass systems. Methods We investigated the Braile Infant...
Gaseous microemboli (GME) define small bubbles as < 200 microm in size. GME are reported to increase morbidity after cardiopulmonary bypass (CPB) and cardiac surgery. To prevent intrusion of GME into the systemic circulation during CPB, arterial line filtration is generally recommended. New trends in oxygenator design promote location of arterial filtration as an integral part of the oxygenator...
A method to collect clinical oxygenator performance data daily is described. At the end of a bypass procedure, the perfusionist fills in a fax-back form designed to automatically input patient-oxygenator performance data into a computer spreadsheet. Multiple blood gases, FiO2, gas and blood flow data, venous oxygenator blood inlet conditions (hemoglobin, O2 saturation, hematocrit and temperatur...
The Terumo Capiox SX18R is a commercially available, low prime, reverse phase, hollow fiber membrane oxygenator. The oxygenator consists of a 1.8 m2 microporous polypropylene hollow fiber bundle, a 2200 cm2 tubular stainless steel heat exchanger, and an open hard shell venous reservoir with integral cardiotomy filter. The Terumo Capiox SX18R oxygenator was evaluated to determine its clinical ox...
Several therapeutic methods require an artificial lung (oxygenator) to replace the physiological function of lung. For instance, in some acute respiratory syndromes, the patient’s lungs are unable to perform their normal function and would need an assistive device to fulfill their performance. Moreover, in cardio-pulmonary bypass, when the heart has stopped pumping, blood is not sent to the lun...